Problem

Pump 

stops 

working or 

runs slow 

Pump will 

not prime.
Pump loses 

prime  

Possible Cause

Bad Power supply

Internal Thermal 

Protector enabled
Impeller is locked 

with debris
Too much debris,

Intake clogged

Air trapped in 

impeller chamber.
Impeller worn out
Pump design is 

NOT self-priming
Air leak
Power interruption

Solution

Check all power connections, GFCI and circuit breakers.
Test using a different power source.
Unplug and allow Pump to cool 30 minutes. Check if Pump is 

clogged before restarting.
Disconnect power and use a pencil eraser to see if Impeller can be 

turned. If not, perform impeller maintenance.
Disconnect power and remove the obstruction.
Use a Pondmaster Pump Bag to reduce future clogging.
Turn off Motor and restart after a few seconds. Repeat three times. 

Replace with a new Impeller.
Position Pump below water level or  fill hose with water and re-start.  

Check intake tubing and connections then repair air leak.
Use a Check Valve to avoid losing prime when power is interrupted. 

 

 

 

 

 

 

 

 

Troubleshooting

:

 

 1

 2

 3

 4

 5

 6

 7

 8

 9

10

11

12

13

14

15

16

Intake Strainer

Motor Cover

Rubber Seal

Impeller 

Impeller Plate

Rotor

Motor Support / Handle

Motor

Screws

1.5” Connector

2 Step 1.5” Barbed Connector

2” Connector

2 Step 2” Barbed Connector

2” to 1.5” Reducer

1.5” Directional Coupling

Motor Cover Screw                          

 #

   

Description 

 

 

WARNING                 RISK OF ELECTRIC SHOCK

 

 

This pump is supplied with a grounding conductor and grounding type 

attachment plug.  NEVER REMOVE GROUND PIN FROM PLUG. To reduce the risk of 

electric shock, be certain that it is connected only to properly grounded, grounding-type 

receptacle.  The national Electric Code requires that a ground fault interrupter circuit 

(GFCI) be installed in every branch circuit supplying the fountain or pond equipment. 

Your dealer can supply GFCI units. 

Do not immerse the plug in water. DO NOT REACH INTO THE WATER TO REMOVE THE 

PLUG. TURN OFF CIRCUIT FIRST. A "drip loop" in the cords should be used. A "drip loop" is 

a loop in the cord below the level of the receptacle or plug that prevents water from 

traveling along the cord. 

WARNING: FOR YOUR PROTECTION, ALWAYS UNPLUG THE UNIT FROM ITS POWER SOURCE 

BEFORE INSTALLING OR SERVICING. DO NOT REACH, REMOVE OR DISASSEMBLE BEFORE YOU 

DISCONNECT POWER.

Thank you for purchasing this Pondmaster product. This Continuous Duty Pump is designed 
to move large volumes of water silently and efficiently through filtration systems or to a 
waterfall, stream or fountain. It incorporates a single-phase capacitor asynchronous motor, a 
high efficiency vortex Impeller in conjunction with a ceramic impeller shaft and bearings to 
save energy while maintaining high output. 
This Pump can be used immersed or inline. Note that when used inline it should be placed 
below the water level since it is not self-priming. Never run this Pump dry.  

WARNING! 

            PONDS ARE DANGEROUS TO SMALL CHILDREN! 

NEVER LEAVE CHILDREN UNSUPERVISED NEAR A POND.

 MODELS   ITEM# 

 

WFP

1900   20210

 

WFP

2550   20215

 

WFP

4850   20220

 

WFP

6100   20225

 

WFP

6600   20230

SAVE THESE 

INSTRUCTIONS

CARE AND OPERATING INSTRUCTIONS

NOTE:

Parts vary on different models. 

When referencing  pump parts 

you must refer to the  ITEM # of 

your pump from pump label. 
Please write your ITEM # here:

PARTS LIST for Pond & Waterfall Pumps 

Model   1900     2550    4850    6100     6600
Item #  20210  20215  20220  20225  20230

 

DANNER MFG. INC. •  Islandia, New York 11749-1489 • Visit our web site at www.dannermfg.com

  

Pond and Fountain Pump with HY-Drive Technology

ZG282   9/10

LIMITED WARRANTY  

E.G. Danner Mfg. Inc. will repair or replace any unit found to be 

defective within three years of original purchase. 

This warranty covers defects occurring under 

normal use and applies to the original purchaser at retail from a certified Pondmaster dealer and 

may not be transferred. 

Cutting or altering cord removing or defacing product labels voids any 

warranty consideration. For warranty repair return only the part that is defective to our factory. 

Please include $10.00 for postage and handling. Damages or injuries resulting from negligence, 

shipping, handling, improper installation, maintenance or misuse of the product are not covered 

by warranty. This warranty gives you specific legal rights. You may have other rights which vary 

from state to state.

To validate this warranty, include your dated proof of purchase (copy of sales receipt from a 

certified Pondmaster dealer). 

Отзывы: