Use the Left / Right keys to scroll to the Power Icon  ..................................................
The frost icon will toggle ON/OFF each time Tick is pressed  .................................................
In this mode, the SmartStat will display the frost icon and will only turn the heating ON 
should the room temperature drop below the set frost temperature (see page 23).
If the heating is turned ON whilst in frost mode, the flame symbol will be displayed.
To cancel the frost protect mode, navigate to the Power button again and press Tick. 

Frost Protection 

Mode Enabled

Frost Mode

SmartStat

Содержание SmartStat

Страница 1: ...SmartStat...

Страница 2: ...1 Model SmartStat Smart Series...

Страница 3: ...erride Optional Features Optional Features Table Time Clock Mode Wiring Diagram Mode 2 Time Clock LCD Display Temperature Display Setting the Clock Setting the Comfort Levels Setting the Temperature T...

Страница 4: ...he heating to be on and what temperature it should reach while it is on It will allow you to select different temperatures in your home at different times of the day and days of the week to meet your...

Страница 5: ...rature You won t have to adjust the thermostat further Any adjustment above this setting will waste energy and cost you more money You are able to temporarily adjust the heating program by overriding...

Страница 6: ...he thermostat as shown in the diagrams on pages 28 31 of this booklet Note For time clock wiring connections terminate as shown on page 38 Step 3 Screw the thermostat back plate securely into the back...

Страница 7: ...6 1 2 3 4 SmartStat...

Страница 8: ...on for 3 seconds SETUP will be highlighted now press and hold the tick key for 10 seconds Use the Left Right keys to scroll between modes Mode 1 Thermostat Mode 2 Time Clock Press the Tick key to conf...

Страница 9: ...follow these steps Connect the Hub to your router with the Ethernet cable provided Connect the power supply to the neoHub The router will automatically assign an IP address to the Hub the Link LED wi...

Страница 10: ...is indicates connection to the SmartHub has been lost The SmartStat uses proximity to detect when you are about to use the touch keys As you approach the thermostat the touch keys and backlight will l...

Страница 11: ...10 Mode 1 Thermostat SmartStat...

Страница 12: ...11 5 10 12 13 14 15 16 9 6 1 2 3 4 8 7 11 Smart Series...

Страница 13: ...or mode 8 Set Displayed when changes are being made to the current set point 9 Program Indicator Displayed during programming 6 level mode to show which level is being altered 10 Program Indicator Dis...

Страница 14: ...ther Room Temp or Floor Temp before the actual temperature value When the SmartStat is set to use both the air the floor sensor the room temperature will be displayed by default To view the current fl...

Страница 15: ...f the display Use the right arrow key to select CLOCK Press Tick to confirm selection Use Up Down keys to set the year Press Tick to confirm selection Repeat the steps to set the Month Date Time Press...

Страница 16: ...6 C Leave 16 00 21 C Return 22 00 16 C Sleep If you only want to use 2 levels you should program the unused levels to For Weekday Weekend programming the four comfort levels are the same for Mon Fri b...

Страница 17: ...wn keys to set the temperature Press Tick to confirm the settings Press the right arrow key LEAVE will now flash and the current settings will be displayed Press Tick to alter LEAVE settings Repeat th...

Страница 18: ...nd the desired temperature value Use the Up Down keys to adjust the SET value Press Tick to confirm settings and return to the main display Note This new temperature is maintained only until the next...

Страница 19: ...t operating program and set a different temperature for a desired period Use the Left Right keys to scroll to HOLD Press Tick to confirm selection Use the Up Down keys to set the desired Hold period P...

Страница 20: ...r the second two digits Press to confirm The display will return to the main screen and display the keypad lock indicator Note The keypad lock indicator is only displayed when the lock is active To un...

Страница 21: ...splay the frost icon and will only turn the heating ON should the room temperature drop below the set frost temperature see page 23 If the heating is turned ON whilst in frost mode the flame symbol wi...

Страница 22: ...set temperature but the thermostat remains active To turn the SmartStat off completely scroll to the Power Icon and hold the Tick key for approximately 3 seconds until the display goes blank The disp...

Страница 23: ...d output as OFF Set a date time for the holiday period to end using the steps below Use the Left Right keys to scroll to HOLIDAY and press Tick Use the Up Down keys to set the year Press Tick Use the...

Страница 24: ...is in Frost Mode The range is 07 17 C The default is 12 C and is suitable for most applications Feature 04 Output Delay To prevent rapid switching an output delay can be entered This can be set from 0...

Страница 25: ...the thermostat has calculated the heating needs 20 minutes to raise the building temperature 1 C and starts the heating accordingly Feature 09 Rate of Change Number of minutes for 1 C temperature ris...

Страница 26: ...ld the Tick button for 3 seconds SETUP will be highlighted now press the tick key once Use the Up Down keys to scroll through features Use the Left Right keys to adjust the setting within each feature...

Страница 27: ...Program Mode Temperature Format DESCRIPTION Used to add zone to the Hub 00 5 0 5 C 01 1 0 C Default 02 2 0 C 03 3 0 C 07 17 C 12 C Default 00 15 Minutes 00 Default 00 10 C 00 Default 00 Built in Senso...

Страница 28: ...o confirm the change and the display will go blank Press the down arrow to highlight the Press the Tick key once to turn the thermostat ON Error Codes E0 The internal sensor has developed a fault E1 T...

Страница 29: ...her common probe values which are 12K or 15K To change the neoStat to use a different probe type follow these steps 10 10K Probe 12 12K Probe 15 15K Probe Press the Tick key to confirm selection Use t...

Страница 30: ...duct must only be installed by a qualified electrician and comply with local installation regulations TO CONNECT BOILER CONSULT BOILER MAKERS DIAGRAM NEUTRAL LIVE 230V SUPPLY IN SWITCHED LIVE TO BOILE...

Страница 31: ...ER MAKERS DIAGRAM NEUTRAL LIVE LS LR 230V SUPPLY IN LS LR ARE NORMALLY THE ROOM THERMOSTAT CONNECTIONS VOLT FREE TO BOILER 230VAC RT1 A2 A1 N L RT2 This product must only be installed by a qualified e...

Страница 32: ...AM L N LS LR LS LR ARE NORMALLY THE ROOM THERMOSTAT CONNECTIONS TO BOILER HEATING VALVE NEUTRAL NEUTRAL LIVE 230VAC RT2 RT1 A2 A1 N L This product must only be installed by a qualified electrician and...

Страница 33: ...ional Remote Probe Connections RT1 A2 A1 N L RT2 230VAC N E SL This product must only be installed by a qualified electrician and comply with local installation regulations REMOTE AIR PROBE Optional L...

Страница 34: ...appear for 2 seconds then you will see the number 1 or 2 flashing Use the Left Right keys to scroll between modes selection will flash Mode 1 Thermostat Mode 2 Time Clock Press the Tick key to confir...

Страница 35: ...34 Mode 2 Time Clock 7 8 9 10 5 1 2 3 4 6 SmartStat...

Страница 36: ...dicator Displayed during programming to show which level is being altered 6 Main Menu Displays which option is currently selected 7 Keypad Lock Indicator Displayed when the keypad is locked 8 Timer St...

Страница 37: ...s the Tick key Use the Up Down keys to select the ON time HOURS and press Tick Use the Up Down keys to select the ON time MINUTES Press Tick to confirm selection Use the Up Down keys to select the OFF...

Страница 38: ...follow these steps Use the Up Down keys to set the override duration e g 02 00 hours Press Tick to confirm settings and return to main display Hold Left and the remaining time will now be displayed Ho...

Страница 39: ...o connect the time clock to the SmartHub Feature 02 Weekday Weekend 5 2 7 Day Programming or 24 Hour Mode The time clock offers three programming methods Weekday Weekend 5 2 Allows you to program 4 on...

Страница 40: ...TRAL LIVE FOR 230V OUTPUT ON A2 LINK LIVE TO A1 VOLT FREE OUTPUT 230VAC RT2 RT1 A2 A1 N L This product must only be installed by a qualified electrician and comply with local installation regulations...

Страница 41: ...40 Notes SmartStat...

Страница 42: ...Model Manual REF 41 Notes 41 Smart Series...

Страница 43: ...42 Notes SmartStat...

Страница 44: ...ipe Building Products Broomhouse Lane Edlington Doncaster DN12 1ES Want More Information Call our telephone support team on 01709 772200 Or view technical specifications directly on our website www po...

Отзывы: