Appendix C
V.35 Technical Information
©
Polycom, Inc.
171
ViewStation FX/VS 4000 User’s Guide
Note 1:
DSR is used as a ring-in indicate if DSR is set to ANSWER
in the V.35 Advanced Configuration screen.
Note 2:
RTS does not act as shown but act as a resync-pulse if
Security/Crypto-Resync is set to ON.
Note 3:
DTR does not act as shown but remains at a high voltage if
DTR is set to ON in the V.35 Advanced Configuration screen.
In-bound Call State Machine
15
RTS = 0 <note 2>
DTR = 0 <note 3>
CRQ = 0
All signals goes low if Far End or User hang up
is detected
DSR = 1 to 0, OR DCD = 1 to 0
A falling edge on DSR or DCD are interpreted
by the VS4000 as a Hang-up.
16
IDLE
DTR = 0 <note 3>
RTS = 0 <note 2>
CRQ = 0
IDLE
RI = 0
DLO = 0
ACR = 0
DSR = 0
State
ViewStation FX or VS4000 Signals
Network Equipment Signals
1
Initial State:
DTR = 0 <note 3>
RTS = 0 <note 2>
CRQ = 0
Initial State:
RI = 0
DLO = 0
ACR = 0
DSR = 0
USER INITIATES CALL
2
DTR = 1<note 3>
3
Wait 10 ms
4
CRQ = 1
5
PND = 1
6
Set Digit (NB1,NB2,NB3,NB4)
7
DPR = 1
8
PND = 0
9
DPR = 0
10
If not last digit go to state 4 else continue
Содержание ViewStation FX
Страница 1: ...ViewStation FX VS4000 User s Guide VS4000 User s Guide February 2001 Edition 3151 10713 001 A1 ...
Страница 2: ......
Страница 6: ......
Страница 14: ...Contents ViewStation FX VS4000 User s Guide xiv www polycom com ...
Страница 178: ...Chapter 6 Troubleshooting ViewStation FX VS 4000 User s Guide 164 www polycom com ...
Страница 196: ...Appendix C V 35 Technical Information ViewStation FX VS 4000 User s Guide 182 www polycom com ...
Страница 210: ...Appendix D PRI Technical Notes ViewStation FX VS 4000 User s Guide 196 www polycom com ...
Страница 212: ...Appendix E Frame Rate Specification For ViewStation FX VS4000 ViewStation FX VS 4000 User s Guide 198 www polycom com ...