background image

Polycom VBP 7301 Hardware Installation Guide

 Physical Installation

© 2015 Polycom, Inc. All Rights Reserved.

9

Connecting the Power and Cables

The Polycom VBP 7301 comes with an AC power cord for connecting the unit to 

the AC outlet.

Warning

Warning

Always connect the AC power cord to an AC outlet suitable for the power 
supply per the Power specifications listed in this document in order to 
reduce the risk of damage to the 7301 power supply.

1.

Connect one end of the AC power cord to the 7301 input power socket and 

the other end to the AC outlet. You may need to apply a bit of force to 

properly position the plug in the power socket.

Caution

Caution

Secure the AC power cord to a cable management system using a fastener 
or tie wrap to insure the 7301 does not hang from the AC outlet. 

2.

If connecting to an Internet router, Internet DMZ switch, cable modem or 

DSL modem, connect the Ethernet cable to the WAN Interface port (Port 2) 

on the 7301 and the other end to the WAN device.

Connecting to the Polycom VBP 7301 for the 
First Time

The Polycom VBP 7301 is pre-configured with the IP address 192.168.1.1 on 

the LAN interface port (Port 1).

1.

Connect the 3-pin female power cord plug to the power socket on the 

VBP 7301. Connect the other end to an AC wall outlet.

2.

Turn on the 7301 power switch.

3.

Make sure that the power and status LEDs on the front panel are solid 

green after the 7301 powers on.

4.

Connect a computer to the LAN interface port (Port 1) using an Ethernet 

cable or connect to an Ethernet switch (using the IP address 192.168.1.2 

and subnet mask 255.255.255.0).

5.

Launch a web browser on the computer and enter the URL string 

http://192.168.1.1.

6.

Press Return. The Polycom VBP 7301 VoIP Operating System (VOS) log in 

window opens:

Содержание VBP 7301

Страница 1: ...14 1 1 March 2015 3725 78313 001A HARDWARE INSTALLATION GUIDE Polycom Video Border Proxy VBP 7301 ...

Страница 2: ...stribution date of the applicable product or software at a charge not greater than the cost to Polycom of shipping or distributing the software to you To receive software information as well as the open source software code used in this product contact Polycom by email at OpenSourceVideo polycom com Disclaimer While Polycom uses reasonable efforts to include accurate and up to date information in ...

Страница 3: ...stallation Polycom VBP 7301 Shipping Contents 9 Desktop Shelf or Tray Installation 9 Rack Mount Installation 10 Connecting the Power and Cables 11 Connecting to the Polycom VBP 7301 for the First Time 11 A Compliance and Certifications USA and Canadian Notices 15 Class A Statements 17 EEA Regulatory Notices 18 Restriction of Hazardous Substances Directive RoHS 19 End of Life Products 19 B Licensin...

Страница 4: ...ns for installing the device and compliance and certification notices It also includes the hardware warranty Polycom VBP 7301 Front Panel LED Indicator Description Power Status Green Off No Power the system is off On Power is good the system is on Data Status Red Off No data access to the IDE drive On Data is being written to the IDE drive ...

Страница 5: ...face must not be on the same network as the WAN or LAN subnets This network cannot be within a subnet contained in a Route statement Port 2 WAN Interface 1 x 10 100 1000 Mbps RJ 45 Ethernet port for connectivity to the WAN or Internet network connectivity Default IP None Port 1 LAN Interface 1 x 10 100 1000 Mbps RJ 45 Ethernet port for LAN network connectivity Default IP 192 168 1 1 USB Ports Curr...

Страница 6: ... are not receiving power No connection between both ends of the network cable Check cable replace cable Green Flashing The adapter is sending and receiving network data The frequency of the flashing varies with the amount of data being transferred Speed Yellow On ACK LINK LED must be on This LED will show the system operating at 1000 Mbps Green On ACK LINK LED must be on This LED shows the system ...

Страница 7: ... cable has the following pinout Specifications and Certifications PIN DB9 Signal DB9 to RJ45 RJ45 Signal PIN 1 DTR Pin 1 to Pin 2 RTS 1 2 TXD Pin 2 to Pin 3 DTR 2 3 RXD Pin 3 to Pin 6 TXD 3 4 DSR Pin 4 to Pin 7 GND 4 5 GND Pin 5 to Pin 4 and Pin 5 SGND 5 6 DTR Pin 6 to Pin 2 RXD 6 7 CTS Pin 7 to Pin 8 DSR 7 8 RTS Pin 8 to Pin 1 CTS 8 Item Description Ethernet Ports 6 x 10 100 1000 Ethernet Serial ...

Страница 8: ...200W MAX AC Input BTU h 682 Warranty 3 Years Environmental Requirement Operating Temperature 0 to 40 C Relative Humidity 10 to 90 non condensing Certifications RoHS Compliant WEEE Compliant Safety UL cUL LVD Gost R Mexico CoC UL AR Emissions FCC Part 15 Class A ICES 003 VCCI Class A KCC CCC C tick BSMI ANATEL Immunity CE MTBF 7301 96 000 hrs ...

Страница 9: ...eating Ensure that the installation site has adequate air circulation and meets the minimum operating conditions for the system as specified in Compliance and Certifications Polycom VBP 7301 Shipping Contents The Polycom VBP 7301 is shipped with the following components Polycom VBP 7301 appliance Rack mount kit AC Power Cord RJ 45 to DB 9 serial craft console port cable Desktop Shelf or Tray Insta...

Страница 10: ...or safe operation of the equipment is not compromised Mechanical Loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and su...

Страница 11: ...g from the AC outlet 2 If connecting to an Internet router Internet DMZ switch cable modem or DSL modem connect the Ethernet cable to the WAN Interface port Port 2 on the 7301 and the other end to the WAN device Connecting to the Polycom VBP 7301 for the First Time The Polycom VBP 7301 is pre configured with the IP address 192 168 1 1 on the LAN interface port Port 1 1 Connect the 3 pin female pow...

Страница 12: ...ts Reserved 7 Enter the following credentials Username admin Password default 8 Click Login The password change window opens 9 Enter credentials that meet the guidelines listed in red and click Change Password 10 When prompted click the link to log on with your new password ...

Страница 13: ...Polycom Inc All Rights Reserved 11 11 Enter your new password and click Login The Polycom VBP 7301 Admin page opens 12 Configure Network parameters and other settings for your Polycom VBP 7301 using the instructions in the Polycom Video Border Proxy VBP Administrator Guide ...

Страница 14: ...uipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interferenc...

Страница 15: ...ith the above conditions may not prevent degradation of service in some situations Repairs to certified equipment should be coordinated by a representative designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own p...

Страница 16: ...of approved equipment without a network interface or equipment not to be connected to circuits with analog ringing supplied NA shall appear The REN is useful to determine the quantity of devices that may be connected to the telephone line Excessive RENs on the telephone line may result in the devices not ringing in response to an incoming call In most but not all areas the sum of RENs of all devic...

Страница 17: ...ñol Spanish Por medio de la presente Polycom declara que el Polycom VBP 7301 cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999 5 CE Ελληνική Greek ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ Polycom ΗΛΩΝΕΙ ΟΤΙ Polycom VBP 7301 ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥΣΙΩ ΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ΙΑΤΑΞΕΙΣ ΤΗΣ Ο ΗΓΙΑΣ 1999 5 ΕΚ Français French Par la présente Polyc...

Страница 18: ... jest zgodny z zasadniczymi wymogami oraz pozostałymi stosownymi postanowieniami Dyrektywy 1999 5 EC Português Portuguese Polycom declara que este Polycom VBP 7301 está conforme com os requisitos essenciais e outras disposições da Directiva 1999 5 CE Slovensko Slovenian Polycom izjavlja da je ta Polycom VBP 7301 v skladu z bistvenimi zahtevami in ostalimi relevantnimi določili direktive 1999 5 ES ...

Страница 19: ...rn authorization for the nonconforming Hardware from Polycom and return the nonconforming Hardware to Polycom s designated repair facility freight prepaid with a statement describing the nonconformity Polycom s exclusive obligations with respect to nonconforming Hardware shall be at Polycom s option to advance replace such Hardware if it is determined to be defective or to refund to End user the p...

Отзывы: