Connect the RealPresence Collaboration Server (RMX) 1800 to a
Power Source
The following restrictions apply to the conductors and connectors that may be used to ground the unit
when rack mounted:
• When using bare conductors, they must be coated with an appropriate antioxidant compound
before crimp connections are made. Tinned, solder-plated or silver-plated connectors do not have
to be prepared in this manner.
• The same bolt assemblies should not secure multiple connectors.
• Listed fastening hardware must be compatible with the materials being joined and must be preclude
loosening, deterioration and electrochemical corrosion of the hardware and joint materials.
Procedure
To connect RealPresence Collaboration Server (RMX) 1800 to AC power:
»
Insert the power cable into the power connector on the rear panel of the RealPresence
Collaboration Server (RMX) 1800 system.
Warning:
Use only the Polycom-supplied AC power cable
• Do not connect the green or green-yellow wire to the system single-point ground
screw.
Connect Cables to the RealPresence Collaboration Server (RMX) 1800
This section outlines the way to connect the cables to the RealPresence Collaboration Server (RMX)
1800.
Procedure
To connect the cables to the RealPresence Collaboration Server (RMX) 1800:
1.
Connect the management network cable to
LAN 1
port.
When LAN redundancy is enabled, LAN 1 is used for both the management and the media and
signaling network connection.
2.
Connect the media and signaling cable to
LAN 2
port.
By default this port is used for signaling, but when LAN redundancy is enabled, LAN 2 is the
backup of LAN 1 port.
Appliance Edition Installation
Polycom, Inc.
18