Polocool PC-35AP/C Скачать руководство пользователя страница 1

USER MANUAL

NC 34/BP

NC 39/BP

PORTABLE TYPE AIR CONDITIONER

Thank  you  for  selecting our quality air conditioner. please be sure to read this user manual

carefully before using. Any question, please contact the professional service for help. 

For

Thank you for selecting our quality air conditioner. Please be sure to read this user manual carefully before using. 

POLOCOOL Portable Refrigerated Air Conditioners are imported and distributed throughout Australiasia by NOBO. 

Any enquiries should be directed to NOBO on 1800 my nobo or 1800 69 6626 in the first instance. 

PORTABLE REFRIGERATED AIR CONDITIONER

USER MANUAL

For

PC-53AP/C  19,000 BTU(5.5kW)
PC-44BP/C  15,000 BTU(4.4kW)

POLO

COOL

POLOCOOL

              

Australia 

 ABN 80 749 103 558

17 Brett Drive, Carrum Downs, VIC 3201   

www.nobo.com.au

Содержание PC-35AP/C

Страница 1: ...ditioner Please be sure to read this user manual carefully before using POLOCOOL Portable Refrigerated Air Conditioners are imported and distributed throughout Australiasia by NOBO Any enquiries shoul...

Страница 2: ...filter cleaning Do not place the air conditioner or plastic window slider in direct sunlight For maximum cooling efficiency keep the exhaust hose as short and as free of bends as possible Clean the f...

Страница 3: ...CONTENTS Introduction 3 Installation 6 Control panel 10 Operation of control panel 10 Operation of remote control 12 Water drainage methods 14 Maintenance and service 15 Trouble shooting 17 2...

Страница 4: ...ughts 4 Multi Storey Buildings Insulation Insulated roofs and walls reduce the amount of heat entering the room Windows admit heat into the room This heat can be reduced if the windows are protected f...

Страница 5: ...rge open areas Close all doors and windows in the room being cooled Do not place the air conditioner in direct sun light Close all curtains in the room being cooled For maximum cooling COOLING MODE se...

Страница 6: ...let grill 2 Lower air inlet grill 3 Higher air inlet grill 4 Power cord hooks 5 Water tank chassis 6 Water drain mouth 7 Plug Fig 1 Fig 2 3 6 5 4 2 1 3 2 3 4 7 5 6 This portable air conditioner is a s...

Страница 7: ...7 the exhaust hose to the hot air outlet grill at the back of the appliance discharge to the nearest window The length of the air exhaust hose is 00mm use the minimum length when working o keep the ai...

Страница 8: ...ection approximately 3 to 4 turns making sure that the hose wire is well threaded into the hose inlet and outlet The hose inlet and outlet cannot be installed unless the hose ends have been fully exte...

Страница 9: ...g 6 If the air exhaust hose needs to be bent the correct method is shown below Fig 7 Incorrect or excessive bending of the exhaust hose will cause loss of cooling and possible malfunction Fig 8 7 Fig...

Страница 10: ...efer to illustration for minimum and maximum window openings Additional complete window kits may be purchased from NOBO to enable pre installation in windows in other rooms Insert Altitude unlimited d...

Страница 11: ...ating R DRY MODE LIGHT illuminated when in DRY mode S COOLING MODE LIGHT illuminated when in COOLING mode OPERATION OF CONTROL PANEL The operating temperature ranges for cooling and dehumidifying are...

Страница 12: ...DE button to select FAN mode To select fan speed press FAN SPEED button repeatedly until the required speed is selected HIGH MED LOW The fan speed AUTO can not be selected in FAN mode NB In FAN mode t...

Страница 13: ...o direct sunlight or leave it near sources of heat COOL DRY FAN HIGH MED LOW SWING TIMER ON TIMER OFF MODE FAN SWING ON OFF TIMER AUTO TIMER selection MODE selection FAN speed selection temperature ti...

Страница 14: ...rs one hour intervals can be selected Press the TIMER button again to confirm the timer setting the TIMER INDICATOR LIGHT lights up and keeps flashing to indicate the timer is activated At the end of...

Страница 15: ...t until no more water drains from the outlet This air conditioner is equipped with the very latest MIST technology which means that the water tank does not have to be emptied This has been verified by...

Страница 16: ...ent and dry it thoroughly in a shaded place Insert the filters back into their original positions Fig 21 MAINTENANCE AND SERVICE MAINTENANCE METHODS Before cleaning or maintenance turn the appliance o...

Страница 17: ...rain pan and dispose of the water Tilt the unit by lifting it at the front to ensure all water is removed from the water tank Then operate the unit in fan mode for half a day until the pipe is dry Win...

Страница 18: ...ng on Is timer on Wait for timer to count down or cancel timer setting by pressing Is compressor light illuminated Wait 3 minutes from turning on safety device prevents compressor which provides cooli...

Страница 19: ...illing water when the air conditioner is used in dry mode and the mist motor is not operating 17 NOBOCOOL NC 49DP C SPECIFICATIONS TECHNICAL SPECIFICATIONS 1 Polocool PC 53AP C 2 Polocool PC 44BP C Ra...