background image

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Double beam

 

 

Installation And  
Commissioning 
manual

 

 

 

POLITEC s.r.l.

 

Содержание Sandor Plus

Страница 1: ...Double beam Installation And Commissioning manual POLITEC s r l ...

Страница 2: ...beam tower is fully watertight once the cover and end caps have been correctly filled at the end of the installation Use the cable glands supplied on the tower for all cabling must pass through the lower end cap using the cable glands supplied Avoid any type of obstruction between the transmitter and receiver Avoid installing the receivers beams in a position where direct sunlight at the same angl...

Страница 3: ...mponent list N Part Q tà Desciption 1 1 Mounting plate 2 1 Front cover 3 2 Front cover top end caps 4 2 Trasmitter receiver optic 5 1 Flat cable 6 1 Receiver trasmitter P C B Terminal board 7 1 P C B 8 4 Bracket ...

Страница 4: ...4 Mounting the bracket A palo Insert the bracket back to mounting plate Pole mounting Wall mounting Diameter 50 mm ...

Страница 5: ...5 Installation example Pole mounting Wall mounting Wall mounting With interposed brakets ...

Страница 6: ...ams Rx Rx Tx Rx Rx Tx Rx Tx Rx Tx Rx Tx Rx Tx Tx Tx Application in couple TX RX crossed beams Tx Rx Tx Rx Tx Rx Rx Application in perimeter control Rx Rx Rx Rx Tx Tx Tx Tx Application in couple parallel beams Rx Rx Tx Rx Rx Tx Rx Tx Rx Tx Rx Tx Rx Tx Tx Tx ...

Страница 7: ...er optics towards its corresponding receiver and vice versa repeat for all the beam pairs This is achieved by manually positioning the lens holder horizontally and vertically using one of the two screws which ever is more convenient to be found above the lens Horizontal alignment Vertical alignment ...

Страница 8: ...AND with 12 beams 1 and 2 interrupted 12 AND random CCTV camera connections Sync Output Tx Antimasking Enviroment disqualification 12 Beam 1 Interrupted 12 Beams 1 and 2 Interrupted 2 4 x 0 22 2 4 x 0 22 Cavo Multiplo Schermato 2 x 0 75 8 10 x 0 22 Cavo coax 75 ohm 2 x 1 5 2 4 x 0 22 2 4 x 0 22 24 Vca 24 Vca G IN AND SGN LOW S OUT S OUT BEAM ANTIMASK Alimentazione riscaldatori Bypass temporaneo de...

Страница 9: ...ynchronisms out are the transmitters which are connected with receivers to which synchronism In have to be linked Sincr Sincr In Out Sincr Sincr In Out Sincr Sincr In Out Rx4 Rx3 Rx2 Rx1 Tx4 Tx3 Tx2 Tx1 Tx4 Tx3 Tx2 Tx1 Rx4 Rx3 Rx2 Rx1 Rx4 Rx3 Rx2 Rx1 Tx4 Tx3 Tx2 Tx1 ...

Страница 10: ...nding to the beam to be aligned Phase 3 Connect the Voltmeter using the cable supplied to the corresponding receiver test point move the transmitter optics slightly in both axes horizontal and vertical until the maximum voltage is obtained Repeat with receiver optics Phase 4 Once the alignement is obtained replace the dip switch in ON Phase 5 Repeat the above procedure for all beam pairs after whi...

Страница 11: ...11 The optical identifications are factory set Transmitter ...

Страница 12: ...12 The optical identifications are factory set The optical identifications are factory set Receiver ...

Страница 13: ...iver test point move the transmitter optics slightly in both axes horizontal and vertical until the maximum voltage is obtained Repeat with receiver optics Phase 4 Once the alignement is obtained replace the dip switch in ON Phase 5 Repeat the above procedure for all beam pairs after which reinsert into OFF position the TEST P SET Link Per la taratura completa del dispositivo occorre porre la sche...

Страница 14: ...e in ON after each set up Move the dip switch 1 in OFF Move the dip switch 2 in OFF Replace in ON after each set up Move the dip switch 3 in OFF Replace in ON after each set up Move the dip switch 4 in OFF Replace in ON after each set up Reinsert the Jumper TEST POINT SET into OFF position at the end of set up ...

Страница 15: ...nterrupted for more than 2sec 3 SYNC WIRE ON Environment disqualification with low signal on 2 optics random 4 SYNC AUTO ON Environment disqualification with low signal on 1 optic random Attention for 3 RX version only Jumper beam exclusion ray 1 Attention for 2 RX version only Jumper beam exclusion ray 1 2 ...

Страница 16: ...tions are triggered the LOW SIG led lights up and the Enviroment Disqualification output signal will be on the terminal board OPEN COLLECTOR N B When the LOW Sig jumper is in ON position and when the OPEN Disqualification intervenes the barrier is excluded returning to normal function as soon as the fog lifts LED ALM Alarm confirmation LED Normally OFF indicates and alarm when lit The condition on...

Страница 17: ... The first two beams at the bottom can be excluded while the remaining beams continue to function The function can also be programmed through remote control by entering a negative command 12V on the terminal marked BEAM on the terminal board RND DLY ON Each time the alarm is triggered with a random delay that varies between 0 and 1 seconds This function is used to confuse and deceive any intruder ...

Страница 18: ... the terminal G IN An impulse sent to the negative will block the barrier alarm output for a period of about 60 seconds This command is used when beams need to be crossed to enter or exit without triggering the alarms and without the need for disconnecting and reconnecting the installation that requires bringing the keyboard or keys outside the protected area SETTING MODELS 3 RX Jumper setting on ...

Страница 19: ...operation up to 50 Alignment angle 10 Vertical 180 Horizontal Detection system And Or on Tx e Rx AND 1 e 2 beam Detection output Random can be inserted Piloting AND REMOTE AND 1 e 2 beam External cover IR trasparent plastic Top Cap Tamper protected Protection rating IP 54 Model 9200 9400 9600 9800 Total number of beams 2TX 2RX 4TX or 4 RX 3TX 3RX 4TX 4RX Power requirements 12 16Vdc Power consumpti...

Страница 20: ...20 POLITEC s r l Via Adda 66 68 20040 Bellusco Mi Italia Tel 39 0 39 6883019 r a Fax 39 0 39 6200471 www politecsrl it E mail info politecsrl it ...

Отзывы: