1.1 Preface 

Thank you for choosing the products of Polimek and your confidence in our company. 

Your system has been designed and manufactured to meet the most demanding requirements of professional access 

control applications. AII components of your system have been selected with utmost care and thoroughly tested to 

ensure optimal performance and reliability. 

To safely  operate  your  product with maximum performance and service life  please  please  follow the instructions written 

in this manual carefully, and keep it for future reference. in case of any operational questions or unexpected issues 

please refer to the explanations contained in this document. 

To obtain technical support or replacement parts please contact  Polimek  Technical Service Department by E-mail 

or telephone. 

Polimek Technical Service Department: Telephone: +90 232 328  16 45 ext:  128  E_mail: [email protected] 

Polimek reserves the right to change the contents of this document without prior notice! 

1.2 General lnformation on Turnstiles 

Turnstiles are devices that enable passage control and prevent uncontrolled or unauthorized passages in stadiums, 

sports halis, leisure facilities,  business centers, public transportation areas, museums, banks, industrial facilities and all 

premises where access control in entry and exit is required. 

As passage controlling units, turnstiles have the ability to work with various types of access control system such as 

barcode,  magnetic card, proximity card readers, tokens, buttons ete. Polimek turnstiles are designed for bi-directional 

operation while featuring simple mode selection by a dip switch for restricted, one way controlled or free passage. 

The turnstiles are made of stainless steel or electrostatic powder coated DKP sheet metal. in double-sided models, two 

separate passage systems are integrated into a single structure. As the turnstiles are firmly anchored on a wide surface 

area, the overall structure is well balanced and robust. Due to their structural characteristics, turnstiles are suitable for 

outdoor installations where they can be exposed to rain, wind, sunlight and similar conditions. AII internal mechanical 

components are galvanized for protection against corrosion. 

Our turnstiles are certified with "T SEK product quality" (A Turkish certification of quality) and CE Declaration of 

Conformity. 

1.3 Full Height  Turnstile Models 

ıe:r J.12 o

iSTE 

3

1

1

DD-75-181 R(2) 

Y.T.13.07.17 

Содержание BT 302 GL

Страница 1: ...OIME _ I I FULL HEIGHTTURNSTILE INSTALLATION ANID MAINTENANCE HANDBOOK www polimek com tr...

Страница 2: ...DD 75 181 R 2 Y T 13 07 17 2...

Страница 3: ...SETUP AND OPERATION 9 5 1 Power and Ground Connections 5 2 Control Board Connections 5 3 Wiring Diagrams 5 3 1 Control Board Terminals 5 3 2 Internal Wiring Diagram 5 4 Control Board Settings 5 4 1 I...

Страница 4: ...on Turnstiles Turnstiles are devices that enable passage control and prevent uncontrolled or unauthorized passages in stadiums sports halis leisure facilities business centers public transportation a...

Страница 5: ...and fuse values when performing any work on the turnstile Warning labels and power supplies may vary depending on the turnstile model and type WARNING To avoid shock hazard AC power connections must b...

Страница 6: ...erating Conditions 1 More than one person must not attempt to pass at the same time 2 Turnstile must not be forced kicked abused or tempered with to gain passage without authorization 3 Turnstiles mus...

Страница 7: ...eight Turnstile Table of Specifications Lock pins Manual Motor Driven Movement Lock Control Stop Structural Materials Rotor Arm Arm Configuration BT 312 S D 3 Arms 120 BT 402 S D 4 Arms 90 BTE 312 S D...

Страница 8: ...ides dry contact relay output for each direction An optional counter can be used 14 Electronic control unit of the turnstile is protected against water for outdoor installations 15 Turnstiles can work...

Страница 9: ...FUSE 3A ERT N F FUSE Warning Power and grounding connections must be made by a qualified electrician in accordance with the relevant local regulations using appropriate materials Proper grounding mus...

Страница 10: ...et and cable tumber tags when replacing board and other parts 3 Connect cable leads into the screw type connector Passage Confirmation Relay NO Normally B A Open Dry Contact Com Control lnput Terminal...

Страница 11: ...n collector input 8 8 8 8 8 8 Optional counter 1N4001 or similar Busy Out or or TRN1202 0 5 1 sn busy B A A B Enable Gnd Passage confirmation dry contact output Use with access control systems counter...

Страница 12: ...3 External Module Connector Motor Driver Drop Arm Control etc 14 Enable Disable inhibit A Board Serial Number B Stock Code C Production Number D Board Model SN Res 24V B A A B N O N O Com Com Gnd Gnd...

Страница 13: ...turnstile for one way passage 5 4 2 Dip Switch Settings Time out and mode settings of the turnstile are selected by the dip switch located on the control board as explained below 1 Bi directional cont...

Страница 14: ...the mechanism 5 5 Hydraulic Damper Adjustment Manual Models Note Damping factor is increased when dial is turned clockwise Once the adjustment is done tighten the stop screw while holding the dial st...

Страница 15: ...ilable appropriate metal polishing compounds can be used for removal of tougher stains The recommended frequency of cleaning depends on the local environment as explained in table below Do not wash th...

Страница 16: ...chnical Service Personnel Description of Fault Possible Cause Recommended Action No power indicators buzzer locks off Rotor free wheels when power is on Note Ensure Emg terminal is not activated and d...

Страница 17: ...Faulty motor 1 Loose photo sensor connector 2 Misaligned bent or contaminated photo sensor 3 Faulty photo sensor 1 Too low motor speed setting on motor driver board 2 Loose or oil contaminated drive...

Страница 18: ...DD 75 181 R 2 Y T 13 07 17 18 7 3 Mechanism Assembly Exploded Diagrams...

Страница 19: ...lenoid 5V 20 02 02 0323 20 02 03 0027 10 00 10 0023 20 02 07 0013 20 02 07 0029 20 03 01 0399 30 01 14 0006 10 09 02 0001 10 02 00 0001 10 00 10 0001 20 02 00 0041 20 02 00 0098 30 01 01 0020 10 01 23...

Страница 20: ...LES HALF HEIGHT TURNSTILES PEDESTRIAN GATES SPECIAL DESIGN TURNSTILES FREE PASSAGE RETAIL LINE TURNSTILES lgili Direktifler Relevant Directives 2006 42 EC Makine Emniyet Y netmeli i Machine Safety Dir...

Страница 21: ...ollowing the date of purchase excluding failures resulting from physical damage incorrect installation misuse tampering and similar reasons beyond manufacturers control 1 Any tampering or damage on wa...

Страница 22: ...DD 75 181 R 2 Y T 13 07 17 23...

Отзывы:

Похожие инструкции для BT 302 GL