47
FEATURES AND CONTROLS
Instrument Cluster
Diagnostic Display Code Definitions
Diagnostic Codes
Component
Condition
SPN
FMI
Intake Air
Temperature Sensor
Data Erratic, Intermittent Or Incorrect
105
2
Voltage Above Normal, Or Shorted To High Source
105
3
Voltage Below Normal, Or Shorted To Low Source
105
4
Abnormal Rate Of Change
105
10
Data Valid But Above Normal Operating Range - Least
Severe Level
105
15
Engine Temperature
Sensor
Data Valid But Above Normal Operational Range - Most
Severe Level
110
0
Data Erratic, Intermittent Or Incorrect
110
2
Voltage Above Normal, Or Shorted To High Source
110
3
Voltage Below Normal, Or Shorted To Low Source
110
4
Abnormal Rate Of Change
110
10
Data Valid But Above Normal Operating Range - Least
Severe Level
110
15
Data Valid But Above Normal Operating Range - Moderately
Severe Level
110
16
Data Valid But Below Normal Operating Range - Least
Severe Level
110
17
System Power
Data Valid But Above Normal Operational Range - Most
Severe Level
168
0
Data Valid But Below Normal Operational Range - Most
Severe Level
168
1
Voltage Above Normal, Or Shorted To High Source
168
3
Voltage Below Normal, Or Shorted To Low Source
168
4
Data Valid But Above Normal Operating Range - Moderately
Severe Level
168
16
Data Valid But Below Normal Operating Range - Moderately
Severe Level
168
18
Engine Speed
Data Valid But Above Normal Operational Range - Most
Severe Level
190
0
Data Valid But Below Normal Operational Range - Most
Severe Level
190
1
Data Erratic, Intermittent Or Incorrect
190
2
Mechanical System Not Responding Or Out Of Adjustment
190
7
Received Network Data In Error
190
19
Condition Exists
190
31
Gear Sensor Signal
Data Erratic, Intermittent Or Incorrect
523
2
Voltage Above Normal, Or Shorted To High Source
523
3
Voltage Below Normal, Or Shorted To Low Source
523
4
Abnormal Update Rate
523
9
ECU Memory
Bad Intelligent Device Or Component
628
12
Out Of Calibration
628
13
Calibration
Out Of Calibration
630
13
Crankshaft Position
Sensor
Data Erratic, Intermittent Or Incorrect
636
2
Abnormal Frequency Or Pulse Width Or Period
636
8
Injector 1 (Front)
(MAG) (SDI Port
Injector)
Voltage Above Normal, Or Shorted To High Source
651
3
Voltage Below Normal, Or Shorted To Low Source
651
4
Current Below Normal Or Open Circuit
651
5