11.10
9928492 R04 - 2017-2018
RZR
XP 1000 / XP4 1000 Service Manual
© Copyright Polaris Industries Inc.
• Loose female terminal in an electrical connector.
NOTE
If the terminals in question are the correct size/series,
always use PV–43526 to test the drag when inserting
and removing the test terminal adapters. Compare the
effort to the drag against the known good tester
terminal for reference.
• Poor terminal to wire crimp.
• Terminal crimp that occurred at least partially on
insulation instead of the conductor wire strands.
• Terminal fretting corrosion
• Contamination/moisture corrosion
• A full or partial break of the conductor wires in the
insulation, with or without visible insulation damage.
• Improper routing, especially when it leads to chaffing
or heat damage, especially near exhaust.
You may need to use different techniques to duplicate
these concerns. These include but are not limited to:
• Moving the harness by wiggling it or flexing certain
areas.
• Pulling at or near the suspected connector.
• Pushing in different directions to flex the connector
body and try to isolate poor connections.
• Changing the temperature. This can be accomplished
with either heat guns or cold air guns.
WARNING
Always exercise caution when using these tools, and
use them for short periods of time when changing the
temp of an area. Failure to do so can lead to Serious
injury and/or damage to the machine.
TESTING CURRENT FLOW (AMPERAGE)
Performing a current flow test requires the meter leads
be inserted into the correct cavities in the meter, and be
placed in series in the circuit to be tested. Refer to your
Digital Multi Meter’s owner’s manual for potential model
specific instructions. Ensure you are using acceptable
adapters to avoid damaging the connector terminals.
Connector Probing Guidelines, page 11.7
NOTE
As there are very infrequently amperage specs
provided for circuits/components, please only perform
this test when advised in the manual.
CAUTION
Many circuits on this machine will exceed the 10 Amp
fuse in most Digital Multi Meters in normal operation.