EPS TROUBLESHOOTING (USING DIGITAL WRENCH®)
Troubleshooting
Procedure Advises
Digital Wrench
↓
Connect Digital Wrench
to Diagnostic Connector
↓
Turn key to “On”Position
→
Is Digital Wrench able to
establish a connection to
EPS?
→
→
No
→
Check wire harness for
damaged/shorted CAN
bus wires. Repair or
replace harness if
necessary
Yes
↓
↓
Follow Digital Wrench
instructions
Trace/Repair CAN bus
wiring and ignition power
wires
←
No
Is DW able to establish a
connection to the ECM?
↓
Yes
↓
Replace Power Steering
Module if any of the Error
codes are present from
Table 1.
Perform further testing if
Error Codes are present
from Table 2.
Replace EPS
TABLE 1
• Position Encoder Error
• EPS Software Error
• Steering Torque Sensor Full Failure
• Steering Excessive Current Error*
• Steering Over Current Shutdown*
• Phase Sensing Over Current
• Phase Sensing Excessive Current
• Torque Sensor Range
• Rotor Encoder Communication
• Rotor Encoder Variance
• SEPIC Voltage Low/High
• EEPROM Failure
*These Error Codes must have multiple occurrences or you must be able to duplicate the condition before replacing
the EPS unit.
TABLE 2
•
EPS Inverter Temperature Test
1. Verify that the Power Steering module heat sink surface (top
surface) is clean and free of mud and dirt. Make a note of how
much debris was on heat sink before cleaning. Record all power
steering error codes. EPS inverter temperature can be monitored
through Digital Wrench.
2. Allow vehicle to set and cool for at least 2 hours.
3. Drive vehicle for 30 minutes of left and right turning and then
connect to Digital Wrench and read Power Steering Error Codes.
If inverter temperature error code is present, replace Power
Steering Module. If error is not present, Module is OK. EPS
inverter temperature can be checked using Digital Wrench.
•
Battery Voltage Over / Under Test
1. Disconnect 2 pin power connector to EPS and verify battery
voltage (12-14 VDC) is present on pins with key on. If voltage is
low, investigate and correct cause. If voltage at pins is correct,
cheak all connections for corrosion, damage, and tightness.
Check pin 3 on 8 pin connector for 12V signal with key on.
•
Calibration Error - Reflash EPS Unit
Содержание RZR PRO XP 2020
Страница 3: ...REVISION INDEX REV DATE CHANGES R01 11 10 2020 Initial Release...
Страница 6: ......
Страница 10: ...1 4 9850068 R01 2020 2021 RZR PRO XP XP 4 Service Manual Copyright Polaris Industries Inc GENERAL INFORMATION...
Страница 144: ...2 58 9850068 R01 2020 2021 RZR PRO XP XP 4 Service Manual Copyright Polaris Industries Inc NOTES MAINTENANCE...
Страница 246: ...3 102 9850068 R01 2020 2021 RZR PRO XP XP 4 Service Manual Copyright Polaris Industries Inc NOTES ENGINE COOLING SYSTEM...
Страница 290: ...5 30 9850068 R01 2020 2021 RZR PRO XP XP 4 Service Manual Copyright Polaris Industries Inc NOTES EFI FUEL SYSTEM...
Страница 358: ...7 20 9850068 R01 2020 2021 RZR PRO XP XP 4 Service Manual Copyright Polaris Industries Inc NOTES TRANSMISSION...
Страница 404: ...8 46 9850068 R01 2020 2021 RZR PRO XP XP 4 Service Manual Copyright Polaris Industries Inc NOTES FINAL DRIVE...
Страница 478: ...9 74 9850068 R01 2020 2021 RZR PRO XP XP 4 Service Manual Copyright Polaris Industries Inc NOTES STEERING SUSPENSION...
Страница 587: ...Symptom and Occurrence Checklist BEEN PRESENT SINCE NEW 51...
Страница 588: ......
Страница 590: ......