9850064 R03 - 2021 650 / 850 Matryx Trail Performance / Crossover Snowmobile Service Manual
© Copyright Polaris Inc.
10.31
KNOCK (DET) SENSOR HARNESS ROUTING
1. The knock (DET) sensor
q
is secured to the cylinder head. Route the knock (DET) sensor harness toward the PTO
side over structure tube and pass harness in between over structure tube and main harness.
2. Secure knock (DET) sensor harness and main harness to the over structure tube with a panduit
w
.
3. Continue to route the knock (DET) sensor harness toward the PTO side of vehicle and connect the knock (DET)
sensor connector
e
to the main harness connector.
4. Secure the knock (DET) sensor connector and harness slack to the main harness with a panduit
w
as shown.