9.30
9850064 R03 - 2021 650 / 850 Matryx Trail Performance / Crossover Snowmobile Service Manual
© Copyright Polaris Inc.
5.
Only install the mixer needle when ready to apply the
adhesive to the components.
Obtaining Adhesive / Mixing Tools Commercially
• The only Polaris-authorized adhesive is Lord 406/19
Acrylic Adhesive (Lord 50 ml PN:3003680).
• Do not use Lord Fusor® Adhesive.
• Lord Dispensing Gun = Lord Pak 50 (3001112)
• Lord Plunger = Lord Pak 50 4:1 Plunger (3004479)
• Lord Mixing Needles = .25" x 6" Needle (3004476)
ADHESIVE APPLICATION
NOTICE
Read and understand the following steps to ensure the
adhesive is applied correctly.
The adhesive has a maximum working time of 6 to 10
minutes at room temperature. It is critical to pre-position
all of the components, screws, nuts, and tools before
applying any adhesive.
All bonded components and mating surfaces must be
cleaned and free from grease, oils, dirt, etc. Clean all
mating surfaces with a soap / water solution and allow to
air dry.
Verify the adhesive and components are at room
temperature 68 °F (20 °C).
NOTICE
The components, and adhesive, must be at room
temperature 68 °F (20 °C) to ensure the adhesive cures
properly.
1.
When you are ready to apply the adhesive, remove
the cartridge end caps. Level the plunger by slowing
squeezing the trigger and expelling the adhesive
from the plug onto a scrap piece of material.
2.
Attach a new mixer needle to the cartridge.
3.
While holding the mixer needle over a piece of scrap
material, slowly compress the caulk gun trigger to fill
the mixer needle. The needle will automatically mix
and dispense the correct volumetric ratio of adhesive
and accelerator.
4.
Continue squeezing the trigger until a needle’s
length of adhesive is expelled.
5.
Quickly apply a 4 mm bead of adhesive to the
component as shown on the following pages. Apply
adhesive to one component at a time.
6.
Carefully install the component and torque the
fasteners to specification immediately. Do not break
the bond once the components are mated.
NOTICE
Never pull apart the parts. Doing so will introduce air
gaps and will require removing the parts and all
adhesive. The bonded parts can be repositioned by
gently sliding them into position.
7.
When not using the adhesive, leave the mixer needle
attached to the cartridge.
8.
If the needle has sat idle for any amount of time,
simply remove the needle, and repeat steps 2
through
4
to
apply
adhesive
to
additional
components.
NOTICE
Do not manually mix the adhesive and accelerator.
Always use a mixing needle to apply the adhesive.