134
Maintenance
Battery Charging (Sealed Battery)
Always verify battery condition before and 1-2 hours after the end of charging.
State of
Charge
Voltage
Action
Charge Time
(Using constant current
charger @ standard amps
specified on top of battery)
100%
12.8-13.0 volts
None, check at 3 months from
date of manufacture
None required
75%-100%
12.5-12.8 volts
May need slight charge, if no
charge given, check in 3
months
3-6 hours
50%-75%
12.0-12.5 volts
Needs charge
5-11 hours
25%-50%
11.5-12.0 volts
Needs charge
At least 13 hours, verify
state of charge
0%-25%
11.5 volts or less
Needs charge with desulfating
charger
At least 20 hours
Содержание 2010 OUTLAW 450 MXR
Страница 1: ......
Страница 3: ...The text is printed on 100 recycled with 40 post consumer waste PCW...
Страница 5: ...1 Visit us at www polarisindustries com...
Страница 42: ...38 Features and Controls Start Button Engine Stop Switch Main Key Switch...
Страница 153: ...149 Maintenance Chain Tension Adjustment Step 1 Step 2 Proper splicelink clip opening position...
Страница 171: ...167 Maintenance Transporting the ATV...
Страница 206: ...202 Maintenance Log DATE SERVICE INTERVAL HOURS TECHNICIAN SERVICE PERFORMED COMMENTS 60 90...
Страница 207: ...203 Maintenance Log DATE SERVICE INTERVAL HOURS TECHNICIAN SERVICE PERFORMED COMMENTS...
Страница 208: ...204 Maintenance Log DATE SERVICE INTERVAL HOURS TECHNICIAN SERVICE PERFORMED COMMENTS...