134
Maintenance
Battery Charging (Sealed Battery)
Always verify battery condition before and 1-2 hours after the end of charging.
State of
Charge
Voltage
Action
Charge Time
(Using constant current
charger @ standard amps
specified on top of battery)
100%
12.8-13.0 volts
None, check at 3 months from
date of manufacture
None required
75%-100%
12.5-12.8 volts
May need slight charge, if no
charge given, check in 3
months
3-6 hours
50%-75%
12.0-12.5 volts
Needs charge
5-11 hours
25%-50%
11.5-12.0 volts
Needs charge
At least 13 hours, verify
state of charge
0%-25%
11.5 volts or less
Needs charge with desulfating
charger
At least 20 hours