![Polaris 2008 ranger 700 xp Скачать руководство пользователя страница 315](http://html.mh-extra.com/html/polaris/2008-ranger-700-xp/2008-ranger-700-xp_service-manual_1571763315.webp)
10.32
ELECTRICAL
Off-Season Storage
To prevent battery damage during extended periods of non-use,
the following basic battery maintenance items must be
performed:
• Remove the battery from the machine and wash the
case and battery tray with a mild solution of baking
soda and water. Rinse with lots of fresh water after
cleaning.
• Using a wire brush or knife, remove any corrosion from
the cables and terminals.
• Charge at a rate no greater than 1/10 of the battery’s
amp/hr capacity.
• Store the battery either in the machine with the cables
disconnected, or store in a cool place.
NOTE: Stored batteries lose their charge at the rate
of 1% per day. Recharge to full capacity every 30 to
60 days during a non-use period. If the battery is
stored during the winter months, electrolyte will
freeze at higher temperatures as the battery
discharges. The chart below indicates freezing
points by specific gravity.
Battery Charging
If battery voltage is 12.8 V or less, the battery may need
recharging. When using an automatic charger, refer to the
charger manufacturer’s instructions for recharging. When using
a constant current charger, use the following guidelines for
recharging.
NOTE: Always verify battery condition before and 1-
2 hours after the end of charging.
Battery Charging Reference Table
Electrolyte Freezing Points
Specific Gravity
of Electrolyte
Freezing Point
1.265
-75° F
1.225
-35° F
1.200
-17° F
1.150
+5° F
1.100
+18° F
1.050
+27° F
WARNING
An overheated battery could explode, causing
severe injury or death. Always watch charging
times carefully. Stop charging if the battery
becomes very warm to the touch.
Allow it to cool before resuming charging.
State of
Charge
Voltage
Action
Charge Time
100%
12.8-13 V
None, check
voltage at 3 mos.
after manufacture
date
None Required
75-100% 12.5-12.8 V
May need slight
charge
3-6 hours
50-75%
12.0-12.5 V
Needs Charge
5-11 hours
25-50%
11.5-12.0 V
Needs Charge
At least 13
hours, verify
state of charge
0-25%
11.5 V or less Needs Charge
At least 20 hours
WARNING
To avoid the possibility of sparks and explosion,
connect positive (red) cable first and negative
(black) cable last.
Содержание 2008 ranger 700 xp
Страница 1: ...POLARIS RANGER XP 700 4X4 RANGER 6X6 SERVICE MANUAL ...
Страница 3: ...POLARIS RANGER XP 700 4X4 RANGER 6X6 SERVICE MANUAL ...
Страница 15: ...1 12 GENERAL INFORMATION SAE Tap Drill Sizes Metric Tap Drill Sizes Decimal Equivalents ...
Страница 118: ...4 8 FUEL INJECTION FUEL TANK Exploded View Fuel Flow ...
Страница 136: ...5 4 BODY STEERING SUSPENSION Lower Body Components ...
Страница 302: ...10 19 ELECTRICAL 10 COOLING SYSTEM Cooling System Break Out Diagram EY N 6OLT 0OWER ...
Страница 327: ...11 1 WIRE DIAGRAM RANGER 700 EFI 4X4 6X6 CHASSIS PAGE 1 OF 2 ...
Страница 328: ...11 2 WIRE DIAGRAM RANGER 700 EFI 4X4 6X6 CHASSIS PAGE 2 OF 2 ...
Страница 329: ...11 3 WIRE DIAGRAM RANGER 700 EFI 4X4 6X6 DASH ...
Страница 330: ...11 4 WIRE DIAGRAM RANGER 700 EFI 4X4 6X6 BREAKOUTS ...