Polario 4 ML Скачать руководство пользователя страница 1

WARNING! Buyer/user assumes all responsibility 

for safety and proper use not in accordance with 

the directions and safety labels.

Drip Loop

GFCI

ONLY

YES

NO

Drip Loop

UL Listed 

Transformer

UL Listed

Transformer

Controller

Controller

Drip Loop

6 ft. 

5 ft. 

6 ft. 

5 ft. 

3 ft. 

GFCI

ONLY

GFCI

ONLY

4ML

7ML & 10ML

GFCI

ONLY

GFCI

ONLY

 4ML

2

1

3

4

11

10-11

7-10ML

6

5

7

10

9

9

8

FUSE

1a. Back Plate

1

2

3

4

7

5

6

WARNINGS AND SAFEGUARDS

Before installation of the Polario™, read and follow these important Warnings and Safeguards.

This product may contain chemicals known to the state of California to cause 

cancer and or birth defects or other reproductive harm. Wash your hand after 

handling this product.
It is your sole responsibilities to verify that the plug and the receptacle are 

clean and free of moisture and salt build up at all times. The receptacle 

must be free of water, salt, calcium, magnesium and dust. Failure to do so 

can cause fire, damage to property, permanent damage to the product and 

personal injury not limited to loss of life. 
Do not plug into extension cord/power strip.
A drip loop must be used when plugging all electrical aquarium devices. A drip 

loop is that part of the cord hanging below the receptacle.
The national code requires that a GFCI (Ground fault circuit interrupter) be 

used in the branch circuit supplying all power to water pumps and electrical 

aquarium equipment. If you do not have a GFCI, have an electrician install 

one prior to operating any aquarium component.

POLARIO

• 

Do not mount controller or transformer where it will come in contact with moisture 

or water.

• 

Never plug Polario™ into any other power supply. 

• 

Do not mount the controller or transformer inside the stand.

• 

Do not operate the pump out of water. 

• 

Do not put your hands or fingers in the propeller well.

• 

Intended for indoor use only.

• 

Mount the controller above the aquarium. 

• 

If the controller or transformer comes in contact with water, do not reach for it. Disconnect power 

first, then retrieve.

• 

Prior to maintenance on any electrical aquarium appliance or maintenance to the aquarium, you 

4ML, 7ML & 10ML 

 

FEATURE

TURBINE DUAL ACTION 

RANDOM FLOW WATER 

 PATENT PENDING

• 

Energy efficient, high flow low voltage water pump 

• 

Bi-directional outputs to simulate natural wave and 

currents of the ocean 

• 

Pre-set random flow and alternating outputs

• 

Random flow rates from approximately 600 GPH to 

2600 GPH (2,300LPH to 10,000LPH) depending on 

the model 

• 

360° degree directional pump mounting bracket with 

magnet mount

must disconnect all electrical aquarium devices.

• 

Routine maintenance is required to ensure the maximum performance and the longevity of the 

Polario™ water pump. See maintenance guidelines. 

• 

The use of a computer grade surge suppressor is strongly recommended. 

• 

Always use the large strainers to prevent small fish, anemones, and/or small invertebrates from 

entering the pump.

• 

If the controller or transformer comes in contact with water or moisture, the warranty is void!

• 

If the Polario™ is used with any other power supply, the warranty is void!

MAGNET MOUNT 

DANGER !

• 

Very strong magnet! Not a toy! Keep out of reach of children! Failure to do so will cause serious 

injury and/or permanent damage to your aquarium.

• 

Keep out of reach of children.

• 

Due to the strength of the magnets, they will attract other metals or magnets with force. When 

installing or handling magnets, there must not be any other magnets or metals in close proximity to 

the magnet holders. Failure to do so can cause serious injury.

• 

Keep away from devices sensitive to magnetic fields, such as pacemakers, data carriers, credit 

cards, electronic equipment and medical devices. Failure to do so may result in permanent 

damage to such devices.

• 

Never allow magnets to snap together.

• 

Always handle magnets one at a time. Once separated keep a minimum of 12in (30cm) apart.

• 

Hold magnets only by the sides. Never get your fingers or hands between the contact surfaces.

• 

When using as an algae cleaner, keep the algae pad free of any abrasive materials to avoid any 

damage to the aquarium. 

 

Note: magnets are very strong and will attract other metals and magnets that will embed themselves 

in the algae pad, thus damaging the aquarium.

TECHNICAL SERVICE DEPARTMENT

Monday to Friday 9 am - 5 pm PST

(805) 383-3566 ext. 102, e-mail: [email protected]

DIRECTIONS FOR INSTALLING

Read and follow all warning and safeguards!

1.  Choose a location for the pump
2.  Install magnet mount  

a.Read all warnings! Handle this product with care,  

   failure to do so will cause injury, damage to the    

   aquarium and or livestock. 

b.Choose desired position of magnetic holder  

c.Separate the magnet holders by twisting units apart  

d.Place the magnet in the desired position in the  

   aquarium, verify that the magnet is flat on the glass 

e.Place the pump and magnet flat on the inside glass  

   and slide the inner magnet until they engage. 

3.  Mount and secure the controller in an area that is dry, 

will stay dry and away from the aquarium.

4.  Mount and secure the transformer in an area that is dry, 

will stay dry and away from the aquarium.

5.  Plug pump into the transformer
6.  Connect the transformer to the controller 
7.  While the unit is in the off position plug in transformer 

directly to a GFCI outlet

8.  Turn unit ON.

PART LIST

1.  Strainers
2.  Main Pump Housing
3.  Ceramic Shaft
4.  Propeller
5.  4x rubber tension bands
6.  360

°

 degree mounting bracket

7.  Magnet mount
8.  Fuse
9.  Controller
10. Transformer
11. Receptable plug

REPLACEMENT PARTS

Part Number

Description

3-4

Polario

TM

 4ML Propeller

3-4

Polario

TM

 7ML-10ML Propeller

MAINTENANCE:

It is the utmost importance to clean and maintain the pump monthly. Remove 

the strainers to access the propeller. Remove the propeller which should slide 

off the motor easily. Now reinstall and verify that the propeller rotates easily 

around the motor. If the propeller binds or there is too much drag created: the 

motor, propeller and ceramic shaft need to be cleaned well. These high speed 

motors attract calcium build up, let the pump soak in a water/vinegar solution 

for a minimum of 1 hour. (3 parts water to 1 part vinegar) Then clean well with 

a small brush. If the pump has not been maintained on a regular basis or if 

high amount of calcium is added this process may be needed to be repeated. 

If there is any noticeable damage to the propeller replace immediately.
Verify the intake strainers are free and clean of all debris at all times

TROUBLE SHOOTING

Controller will not power up and/or pump will not turn on: It is imperative to 

keep  the  pump  clean  and  well  maintained  to  ensure  the  pump  is  in  good 

working order and the propeller and strainer clean at all times, failure to do so 

will cause the 4 ML, 7 ML and 10 ML controller to shut down. At that time the 

fuse will have to be replaced. 

SOLUTION:

1.  Turn off the unit and unplug the transformer 
2.  Remove the back plate of the controller (1a).
3.  Locate fuse and with a flat head screwdriver remove the blown fuse
4.  Replace 1.6 amp fast blow fuse for 4ML and 2.5 amp fast blow fuse for 

7ML and 10ML.

5.  Install back plate of the unit.
6.  Verify that the impeller is clean and free of all debris, the pump is placed 

back into the aquarium and that the strainers are free of all debris.

7.  Restart the unit. 