HP37

Handbook

SL 4.0

4-step ventilation

MAIN SETTINGS (Run Mode)

VENTILATION TEMPERATURE SETTING.

Press 

°C VENT

:

This messagge will be displayed instead of the 

°Set

Ventilation temperature value

 

(start first speed)

.

Press 

or 

to modify, press 

°C VENT

 to confirm.

MINIMUM SPEED SETTING.

Press 

MIN VENT

:

This messagge will be displayed instead of the 

Minimum

Ventilation Speed.

Press 

+

 or 

to modify, press 

MIN 

to confirm.

MAXIMUM SPEED SETTING.

Press 

MAX VENT

:

This messagge will be displayed instead of the 

Maximum

Ventilation Speed

.

Press 

+

 or 

to modify, press 

MAX 

to confirm.

In normal condition ambient  temperature is displayed and in setting coindition flashing
messagge appear.
The normal condition become again after exit from setting mode (auto-exit is performed
after 5 seconds from last key stroke in setting condition).

AMBIENT TEMPERATURE VIEWING

Press  

+

: will be displayed followed by

°Maximum Temperature Recording.

Press 

 -

  :

will be displayed followed by

°Minimum Temperature Recording.

VIEWING TEMPERATURE RECORDING

Values recorder are memory permanent stored: for memory clear keep pushed  

+  

keys

for more than 3 seconds:  

CLEA

  messagge will be composed on display before clearing

operation.

How to connect the line

Connect line on terminals

 L-N

; protect supply with adeguate fuse.

How to connect the sensors

Connect the temperature probe provided as shown  in  the  diagram.  For  remote
connections  use  a standard 0.5-square millimeter two-pole wire  for  each sensor,
taking great care   over  the  connections,  by insulating and sealing the joins carefully.

How to connect the contacts

Connect terminals 

3-7

 /

 ...11-13 

on the  terminal  block (contacts up to 4AMP.AC1).

Output contacts are N.O. (Normally Opened and free of voltage) on wich is aplliable a
4AMP AC1 maximum load.
3-4= Speed 1 contact.
3-5= Speed 2 contact.
3-6= Speed 3 contatc.
3-7= Speed 4 contact.
11-12= Heat  contact.
12-13= Cool  contact.

Other power voltage if you required

COOL

COMMON

HEAT

HP37

230V LINE *

COMMON

SPEED 4

SPEED 3

SPEED 2

SPEED 1

SX TEMPER.

PROBE

 INSTALLATION

As it company policy to continually improve the products the Manufacturers
reserve the right to make any modifications thereto without prior notice. They
cannot be held liable for any damage due to malfunction.