Pocket DSO504 Oscilloscope manual

 

Ⅰ、

Technical parameters: 

1.  

Processor

32 bit ARM Cortex M3 kernel CPU

 

2.  

LCD screen

2.8 inch

 TFTLCD 

3.  

Resolution

320*240

 

4.  

Number of channels

1 channels

 

5.  

Input impedance

>1M Europe

 

6.  

The reference waveform output

10HZ ~ 1MHZ

 

7.  

The measurement bandwidth

0 ~ 4MHZ

 

8.  

The maximum sampling rate

50MS/s

 

9.  

The storage depth

4K byte

 

10.

Maximum input voltage

:4

0V ( x1 probe ), 400V ( X10 probe )

 

11. 

Trigger type

rising edge, falling edge trigger trigger

 

12. 

Scan mode

automatic scan, plain scan, single scan and random scanning 

    13. 

Measurement parameters

voltage deviation, time difference, frequency of signal, signal cycle, signal duty   

                ratio, AC peak-to-peak value, effective value, average value of AC and DC average value 

     

 14. 

Waveform storage capacity

4M   

     

 15. 

Waveform storage quantity

temporary limit 256 

     

 16. 

Power supply

built-in rechargeable lithium battery 3.7V, can also use the power supply for the USB 5V

 

 

Ⅱ、

The appearance of 

oscilloscope 

Содержание DSO504

Страница 1: ...oltage 40V x1 probe 400V X10 probe 11 Trigger type rising edge falling edge trigger trigger 12 Scan mode automatic scan plain scan single scan and random scanning 13 Measurement parameters voltage deviation time difference frequency of signal signal cycle signal duty ratio AC peak to peak value effective value average value of AC and DC average value 14 Waveform storage capacity 4M 15 Waveform sto...

Страница 2: ......

Страница 3: ...Ⅲ The definition of each item on the screen Ⅳ Menu operation short press key to downward selection menu short press key to Upward select the menu ...

Страница 4: ...till be able to display signal waveform NORM is a common scanning mode when the input signal is not satisfied when the trigger condition do not display signal waveform SING is single scan mode the signal is triggered scan sampling and display after the 1 time automatically enter the suspended state Restart after press key NONE is the random sampling display mode this mode don t stop wave scanning ...

Страница 5: ...ust the horizontal position of X axis 8 Output pulse frequency The output pulse frequency modulation by or key 10HZ 2MHZ Press or key or fine tuning of the output pulse frequency 9 Waveform storage Press the or key on the option to save the file number Press key to save waveform options Press key to read waveform options Press key to execute save or read operation Ⅴ Waveform display 1KHZ 100KH ...

Отзывы: