OPERATION
Power ON/OFF/Power Saver
There are 3 different status for inverter: "ON(Power Saver)
”"
INVERTER OFF
”
and "ON
”
When power switch is in "INVERTER OFF
”
position, the inverter is powered off.
When power switch is turned to either of "ON(Power Saver)
”or "
ON", the inverter is powered on.
Power saver function is designed to conserve battery power when AC power is not or rarely required by the loads. In this
mode, the inverter pulses the AC load . Whenever an AC load(greater than 25 watts) is turned on, the inverter recognizes
the need for power and automatically starts inverting and output goes to full voltage. When there is no load (or less than 25
watts) detected, the inverter automatically goes back into search mode to minimize energy consumption from the battery
bank. In "ON(Power Saver)" mode, the inverter will draw power mainly in sensing moments, thus the idle consumption is
significantly reduced.
Remote control
Apart from the switch panel on the front of the inverter, an switch panel connected to the RJ 11 port at the DC side of the
inverter thru a standard telephone cable can also control the operation of the inverter. If an extra switch panel is connected
to the inverter via "remote control port" together with the panel on the inverter case, the two panels will be connected and
operated in parallel.
Whichever first switches from "OFF
”
to "Power saver off' or "Power saver on" it will power the inverter on. If the
commands from the two panels conflict, the inverter will accept command according to the following priority:
Power saver on/Power saver off/Power off, Only when both panels are turned to "Unit Off' position will the inverter be
powered off.
The Max length of the cable is 10 meters.
Never cut the telephone cable when the cable is attached to inverter and battery is connected to the inverter. Even if the
inverter is turned off. It will damage the remote PCB inside if the cable is short circuited during cutting.