Problem solving
Overview
Symptom
Possible cause
Corrective action
PDP temperature too high The dryer has not had the time to
regenerate completely.
Close the valve installed between the
dryer and the application (if permitted)
and have the desiccant regenerated.
The silencers are clogged.
Replace the silencers.
The drain is not working correctly.
Check the drain valve of the filter.
The air flow through the dryer is too
high.
Check for correct application.
The outlet pressure is too low.
Check whether the compressor provides
enough air for the application.
The inlet temperature is too high.
Check the compressor aftercooler.
Free water in the dryer.
Check the water separator (WSD) and
the drain valve of the filters upstream of
the dryer.
The dryer produces a lot
of noise.
Check the silencer and its fixation to
the unit.
Replace the silencer if necessary or
correct its fixation.
Insufficient air leaves the
dryer.
Too much purge air escapes.
Check the condition of the solenoid valve
and replace it if necessary.
LED Service warning /
Service alarm is alight.
Both LED’s are timer-controlled and
will light up after a certain time
(orange LED (warning) after 7750
hours, red LED (alarm) after 8000
hours).
Contact your supplier for maintenance.
Reset the timer after maintenance.
Instruction book
56
2920 1891 00
Содержание PH 230 HE
Страница 1: ...PNEUMATECH PH 230 HE PH 320 HE PH 390 HE PH 530 HE PH 635 HE Instruction book ...
Страница 2: ......
Страница 45: ...5 Installation 5 1 Dimension drawings PH 230 HE in inch Instruction book 2920 1891 00 43 ...
Страница 46: ...PH 320 HE in inch Instruction book 44 2920 1891 00 ...
Страница 47: ...PH 390 HE in inch Instruction book 2920 1891 00 45 ...
Страница 48: ...PH 530 HE in inch Instruction book 46 2920 1891 00 ...
Страница 64: ......
Страница 65: ......
Страница 66: ...No 2920 1891 00 2016 08 Printed in Belgium www pneumatech com ...