![PMD Atlas Compact Скачать руководство пользователя страница 98](http://html1.mh-extra.com/html/pmd/atlas-compact/atlas-compact_complete-technical-reference_1569420098.webp)
98
Atlas® Digital Amplifier Complete Technical Reference
6
GetBusVoltage
40
h
Syntax
GetBusVoltage
Motor Types
Arguments
None
Returned Data
Type
Range
Scaling
voltage
unsigned 16 bits
0
to
2
16
–1
1.3612 mv/count
Packet
Structure
Description
GetBusVoltage
gets the most recent bus voltage reading from the Atlas.
Restrictions
see
DC Brush
Brushless DC
Microstepping
GetBusVoltage
checksum
40
h
15
8 7
0
First data word
read
voltage
15
0