GetEventStatus
31
h
Syntax
GetEventStatus
Motor Types
Arguments
None
Returned data
Type
status
unsigned 16 bits
see below
Packet
Structure
Description
GetEventStatus
reads the Event Status register. All of the bits in this status word are set by the internal
events and cleared by command. To clear these bits, use the
ResetEventStatus
command. The following
table shows the encoding of the data returned by this command.
Restrictions
see
GetDriveFaultStatus
,
DC Brush
Brushless DC
Microstepping
GetEventStatus
checksum
31
h
15
8 7
0
Data
read
Event Status
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Name
Bit(s) Description
—
0–6
(Reserved)
Instruction Error
7
Set to 1 when an instruction error has occurred.
8
(Reserved)
Overtemperature Fault
9
Set to 1 when an overtemperature condition has occurred.
Drive Exception
10
Set to 1 when a disabling drive fault has occurred.
—
11
(Reserved)
Current Foldback
12
Set to 1 when current foldback has occurred.
—
13-15