![Plymovent VSRX Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/plymovent/vsrx/vsrx_user-manual_1569261013.webp)
4.4
VSRX-Rail Location
1. VSRX-Rail
2. Tailpipe
3. Bay door
4. Rail height
5. Distance to vehicle
6. Distance to exit door
a. The VSRX-Rail (1) is mounted at a height (4) between 12 ft
(3,7 m) and 14 ft (4,3 m) over the floor on the side in which
the tailpipe (2) is located.
b. The rail should be mounted 18 in. to 24 in. (457,2 to 609,6
mm) from the body of the vehicle (5), and positioned on the
tailpipe side of the vehicle. Preferably the rail is on or within
the boundaries of the exit door.
c. The rail should be mounted immediately under a sectional
door with a clear height from the track to the door of 4 in.
(100 mm) to 6 in. (150 mm).
d. The recommended distance from the end of the rail to the
door(s) (6) can be found in the table on page 10.