0507060080/011113/H | SIF-700/900/1200/1500/1800/1900/2000 -|SF 7000/9000/12000/15000/18000/19000/20000
EN - 6
every year beside the indicated periodic maintenance. For this
purpose contact your supplier.
The maintenance activities in the table below are strictly
reserved for well trained and authorised service engineers.
If the product does not function (correctly), consult the checklist
below to see if you can remedy the error yourself. Should this
not be possible, contact your supplier.
The following spare parts are available:
After life of the product, dispose it of in accordance with state or
local regulations.
CE declaration of conformity for machinery
We, Plymovent Manufacturing B.V., Wezelkoog 11, 1822 BL
Alkmaar, the Netherlands, herewith declare, on our own
responsibility, that the products:
- SIF-700 / SF 7000 LI/RI (Outdoor)
- SIF-900 / SF 9000 LI/RI (Outdoor)
- SIF-1200 / SF 12000 LI/RI (Outdoor)
- SIF-1500 / SF 15000 LI/RI (Outdoor)
- SIF-1800 / SF 18000 LI/RI (Outdoor)
- SIF-1900 / SF 19000 LI/RI (Outdoor)
- SIF-2000 / SF 20000 LI/RI (Outdoor)
which this declaration refers to, are in accordance with the
conditions of the following Directives:
- Machine Directive 2006/42 EC
- LVD 2006/95 EC
- ErP Directive 2009/125/EC
Alkmaar, the Netherlands, November 1, 2013
.
Ir. F. Coehoorn
Vice President Research & Development
An installation is defined as a combination of several finished products
or components that are assembled by an installer at a given place. The
various parts of the installation are intended to operate together in a
particular environment and to perform a specific task. The entire
installation must comply with the relevant directives and standards. The
assembly instructions given by the manufacturer, as well as the whole
method of installation, must be in accordance with good engineering
practices within the context of installations, as well as installation rules.
Considering the above, the installer will be responsible for completing the
installation and issuing the final CE Declaration of Conformity.
WARNING
Overdue maintenance can cause fire.
WARNING
Always fully
disconnect
the machine from the mains
before carrying out maintenance jobs as mentioned
below. First read the maintenance regulations at the
beginning of this manual.
Component
Action
Freq.
Every 12
months
Flexible adapters Check for airtightness and damages.
Replace if necessary.
X
Impellers
Check for dirt. Clean if necessary.
X
7
TROUBLESHOOTING
WARNING!
After switching off the fan,
wait
at least 30 seconds
before opening the inspection cover.
Symptom
Problem
Possible cause Solution
Motor does not
start.
Fan does not
function.
No mains
voltage.
Check the mains
voltage.
Mains cord
defective
Repair or replace the
mains cord.
Loose contacts.
Repair the contacts.
Thermal relay in
system control
panel defective.
Replace the thermal
relay.
Connection PTC
to frequency
inverter
defective.
Repair connection.
Refer to manual of
frequency inverter.
Motor makes a
humming
sound, but
does not
function.
Extraction
capacity
insufficient or
no extraction
at all.
Motor uses 2
phases instead
of 3.
Repair the phase
connection.
Motor stops
automatically.
Fan does not
function.
Motor defective. Repair or replace the
motor.
Inverted
direction of
rotation of the
motor.
Change the direction
of rotation.
Poor suction.
Extraction
capacity
insufficient or
no extraction
at all.
Inverted
direction of
rotation of the
motor.
Change the direction
of rotation.
Impeller(s) dirty. Clean impeller(s).
Undesired by-
pass.
Check the flexible
adapters.
Vibrations in
fan.
Fan running
unstable.
Imbalance in
fan.
Clean the fan.
Differential
pressure of the
connected filter
system exceeds
capacity of the
fan.
Clean or replace the
filters of the
connected filter
system.
8
SPARE PARTS
Article no.
Description
SIF-700 / SF-7000
0000102362
Fan wheel
0000102357
Motor 3 kW (4 HP)
SIF-900 / SF-9000
0000102269
Fan wheel
0000102358
Motor 5,5 kW (7.5 HP)
SIF-1200 / SF-12000
0000102363
Fan wheel
0321300140
Motor 7,5 kW (10 HP)
SIF-1500 / SF-15000
0000102364
Fan wheel
0321300130
Motor 11 kW (15 HP)
SIF-1800 / SF-18000
0000102365
Fan wheel
0000102359
Motor 15 kw (20 HP)
SIF-1900 / SF-19000
0000102366
Fan wheel
0000102360
Motor 18,5 kW (25 HP)
SIF-2000 / SF-20000
0000102367
Fan wheel
0000102361
Motor 22 kW (30 HP)