0000300349/230420/0 MDB-Diluter PRO
32
ANNEX
Table I
Cable specifications
Connection
Recommended cable
type
Included
Source
locally
For use with
Option
#
MDB-Diluter
1
Panel
HMI (shielded)
2
Panel
SlaveBoard (shielded)
3
SlaveBoard
SlaveBoard
5
Mains cord
H05VV-F 4G4
6
External start/stop
H05VV-F 2X0.75
7
External alert input
8
Relay output 1
9
Relay output 2
20 Control cable (compressed air switch)
H05VV-F 2X0.75
*)
22 Light tower
H05VV-F 7X0.5
23 Motor cable
190 CY 4X4
(shielded)
24 PTC cable
190 CY 2X0.75
(shielded)
*) connected to compressed air switch
Table II Digital inputs
Input
Input
High
Low
IN 5
External signal fan start/stop
start
stop
IN 6
Fire alarm
normal
alarm
IN 9
Fan alarm
alarm
normal
IN 10
Compressed air switch
normal
alert
IN 11
External alarm signal
normal
alert
IN 12
Dustbin level switch
full
not full