Operating the regulator 

This  section  briefly  describes  how  the 
regulator should be operated.  

7.1

 

Description of buttons and display  

 

 

Drawing 1. Keyboard view,  

Legend: 
1.

 

menu item change button 

2.

 

STOP button, value decrease 

3.

 

START button, value increase 

4.

 

mains switch 

5.

 

fuse socket 

After  turning  the  regulator  on,  the  START 
and  STOP  buttons  are  used  to  enable  and 
disable airflow respectively. 

 

 

 

 

Drawing 2. Main display window 

Legend: 
1.

 

preset boiler or hot utility water tank 
temperature, or preset temperature of 
emission,  

2.

 

measured temperature of boiler, hot 
utility water tank, or emission, 

3.

 

signal arrow 

4.

 

SUMMER – hot utility water mode symbol  

5.

 

PRIORITY - hot utility water mode symbol 

6.

 

Boiler regulation mode – PID function, 

7.

 

Room thermostat - this symbol lights up 
when the temperature inside the room 
reaches the preset value contacts are 
disconnected) 

8.

 

alarm symbol 

9.

 

signal of increasing the preset boiler 
temperature due to hot utility water 
heating, 

10.

 

signal decreasing the preset boiler 
temperature due to operation of the room 
thermostat, 

11.

 

service menu symbol 

12.

 

hot utility water temperature sensor, 

13.

 

central heating pump symbol 

14.

 

hot utility water pump symbol 

15.

 

boiler temperature sensor, 

16.

 

emission temperature sensor,  

17.

 

airflow power 

18.

 

fan  symbol  it  this  is  not  visible  – 
regulation  is  off,  it  is  visible  –  regulation 
is on, if it flashes – the regulator is in the 
SUPERVISION mode 

19.

 

hot utility water tank symbol 

20.

 

icons: 

 

Temperature settings 

 

Blow-off time 

 

Blow-off interval 

  Maximum revolutions 

  Minimum revolutions 

 

Settings for hot utility water 

 

Boiler regulation mode 

 

Service menu symbol 

7.2

 

First start-up of the regulator 

Before  the  first  start-up  of  the  regulator,  it 
should  be  programmed  for  the  purposes  of 
cooperation with the given boiler and heating 
system,  in  accordance  with  point  11.9.  It  is 
recommended  that  this  performed  by  a 
person familiar with heating technology. 

7.3

 

Start-up of the regulator 

10 

9  8 

6  5 

11 

14 

12

15 

13 

16 

19 

17 

18 

Содержание ecoMAX 200 W

Страница 1: ...oiler regulator ecoMAX 200 W FOR SOLID FUEL BOILERS WITH A FAN OPERATION AND MAINTENANCE MANUAL ISSUE 1 3 APPLICABLE TO SOFTWARE 10 034 10 035 10 036 2010 04 14 Dzia Zintegrowanego Systemu Zarz dzania...

Страница 2: ......

Страница 3: ...1 CONNECTING TEMPERATURE LIMITER STB 20 11 12 CONNECTING ADDITIONAL THERMAL PROTECTION 20 11 13 SMOOTH FAN START 20 12 Service settings 21 12 1 CENTRAL HEATING PUMP ACTIVATION TEMPERATURE N0 21 12 2 B...

Страница 4: ...erature limiter Therefore it cannot be used instead of a safety temperature limiter The value of the programmable parameters should be selected appropriately to the parameters of the given boiler and...

Страница 5: ...rtable temperature in the heated rooms 3 Information about documentation The regulator manual is a supplement for the boiler manual In particular except for this manual the boiler manual should also b...

Страница 6: ......

Страница 7: ...REGULATOR INSTRUCTION MANUAL ecoMAX 200 W...

Страница 8: ...ng the preset boiler temperature due to hot utility water heating 10 signal decreasing the preset boiler temperature due to operation of the room thermostat 11 service menu symbol 12 hot utility water...

Страница 9: ...l the arrow is in the boiler regulation mode position Use or buttons to set value The method is based on the T1 boiler indication and consists in decreasing of the airflow power from Maximum revolutio...

Страница 10: ...the PID EMISSION mode Moreover after equipping the regulator with an emission sensor it is possible to enable very fast detection of fuel shortage This provides additional saving of heat energy resul...

Страница 11: ...temperature exceeds the preset boiler temperature by 10 C In the SUPERVISION mode the fan is enabled cyclically for short periods in order to prevent the fire from going out and to remove accumulated...

Страница 12: ...e regulator outputs The window shown at Drawing 5 appears and the central heating pump symbol flashes first Drawing 5 Manual control Press START and STOP to change the status of the given output START...

Страница 13: ...REGULATOR INSTALLATION AND SERVICE SETTINGS MANUAL ecoMAX 200 W...

Страница 14: ...d by the regulator where 1 ecoMAX 200 regulator 2 central heating pump 3 hot utility water pump 4 fan 5 room thermostat 6 hot utility water tank 7 central heating system 8 chimney duct 9 boiler T1 boi...

Страница 15: ...of 15 60 C During transport the device cannot be exposed to vibrations greater than those typical of normal road transport 11 Regulator installation 11 1 Environmental conditions Due to the risk of ex...

Страница 16: ...ermal conditions and safety issues a safe distance between active parts of the terminals and the conductive metal elements of the enclosure must be kept Drawing 10 Metal elements of the regulator encl...

Страница 17: ...d with an arrow Drawing 12 Diagram of electric connections with external devices where T1 boiler temperature sensors type CT4 T2 hot utility water temperature sensors type CT4 T3 emission temperature...

Страница 18: ...at least 0 5mm2 Total length of the sensor leads cannot exceed 15 m The boiler temperature sensor CT4 should be fitted in the thermometric pipe situated in the boiler shell Hot utility water temperatu...

Страница 19: ...be filled via hot utility water pump select the hot utility water pump operation mode acc to point 7 9 11 10 Connecting room thermostat To make the boiler more economical and the temperature in the h...

Страница 20: ...l order It cuts off the fan power supply Sensor of the additional thermal protection which operates on low safe voltage should be placed in the thermometric pipe of the water jacket You should provide...

Страница 21: ...eating pump is activated This protects the boiler against retting caused by its being cooled down by hot water returning from the system Disabling the central heating pump on its own does not guarante...

Страница 22: ...e in the heated rooms will drop and the boiler will reach the preset temperature faster and switch to the SUPERVISION mode Yet too long a blockade of the central heating pump will cause the system to...

Страница 23: ...the hot utility water pump when the central heating pump is disabled In order to cool the boiler down operation of the hot utility water pump can be extended by the time r4 Extending hot utility wate...

Страница 24: ...he cases of power supply failure the regulator will resume the operation mode in which it was before the failure 13 Firmware WARNING Values of the following parameters can be modified only by qualifie...

Страница 25: ...threshold Thanks to this a momentary exceeding of the boiler temperature will not cause stoppage of the boiler Before the boiler reaches the P0 temperature the regulator will attempt to drop the exces...

Страница 26: ...temperature limiter STB input jumper is on terminals 1 2 the jumper should be placed only if no temperature limiter is connected check if the additional thermal protection sensor input jumper is on te...

Страница 27: ......

Отзывы: