PLIDCO CLAMP-RING Скачать руководство пользователя страница 2

IP-015 

 

Page 

1

 of 

6

 

25JUN18 

 
 
 

The Pipe Line Development Company 

870 Canterbury Road  •  Westlake, Ohio  44145 

Phone: (440) 871-5700  •  Fax: (440) 871-9577 

Toll Free: 1-800-848-3333 

web: www.plidco.com  •  e-mail: [email protected] 

 

PLIDCO

®

 CLAMP+RING 

INSTALLATION INSTRUCTIONS 

 

!! 

WARNING

!! 

IMPROPER SELECTION OR USE OF THIS PRODUCT CAN RESULT IN 
EXPLOSION, FIRE, DEATH, PERSONAL INJURY, PROPERTY DAMAGE 
AND/OR HARM TO THE ENVIRONMENT. 

 
Do not use or select a PLIDCO Clamp+Ring until all aspects of the application are thoroughly analyzed.  
Do not use the PLIDCO Clamp+Ring until you read and understand these installation instructions. 
 
Every effort has been made to securely package this product prior to shipment.  If you have any 
questions, or encounter any difficulties using this product, please contact: 
 

PLIDCO “DEPARTMENT 100” at 440-871-5700 

toll free U.S. & Canada at 800-848-3333 

READ CAREFULLY 

The person in charge of the installation must be familiar with these instructions and communicate them 
to all personnel involved. 

Safety Check List 

 

 

Read and follow these instructions carefully.  Follow your company’s safety policy and applicable 
codes and standards. 

 

 

Whenever a PLIDCO product is modified in any form by anyone other than the Engineering and 
Manufacturing Departments of The Pipe Line Development Company, the product warranty is 
voided.  Products that are field modified do not have the benefit of the material traceability, 
procedural documentation, quality inspection and experienced workmanship that are employed 
by The Pipe Line Development Company. 

 

 

During the design stage the end user should have communicated the axial force, bending force, 
and/or torsion load requirements, as applicable.  Ensure these loads are listed on the sales order 
acknowledgement or the label on the PLIDCO Clamp+Ring.  Otherwise, the PLIDCO Clamp+Ring 
is designed for a specific axial load in units of force.  As such, do not exceed the maximum end 
restraint indicated on the label of the PLIDCO Clamp+Ring.  Verify the maximum end restraint 
indicated on  the label is sufficient to resist your combination of hydrostatic, dynamic, external, 
bending, torsional and/or thermal induced forces. 

Содержание CLAMP-RING

Страница 1: ...BREW PLIDCO CLAMP RING INSTALLATION INSTRUCTIONS LANGUAGES CLICK ON LANGUAGE DESIRED PLIDCO The Pipe Line Development Company www plidco com 440 871 5700 pipeline plidco com 870 Canterbury Rd Westlake...

Страница 2: ...o all personnel involved Safety Check List Read and follow these instructions carefully Follow your company s safety policy and applicable codes and standards Whenever a PLIDCO product is modified in...

Страница 3: ...of the clamping sections This area should be a smooth curved surface without indentations or flat spots that could adversely affect proper griping 3 Grind pipe welds flush with the outside pipe surfac...

Страница 4: ...f the PLIDCO Fitting if required If the PLIDCO Fitting is not to be welded the PLIDCO Clamp Ring can be positioned closer if desired See Figure 1 for this setup and labelled components of the PLIDCO C...

Страница 5: ...le industry methods should be used to verify bolt preload Figure 2 9 Consult the manufacturer s instructions for torqueing tensioning or other specialized equipment such as SuperboltTM nuts 10 The tie...

Страница 6: ...hould not be allowed near the repair until the seal has been proven Storage PLIDCO Clamp Rings should be stored in a dry environment to prevent any unpainted surfaces from rusting PLIDCO Clamp Rings p...

Страница 7: ...8 7 1 4 45 600 61 900 5 8 7 5 8 53 300 72 300 5 1 4 8 8 61 900 83 900 5 1 2 8 8 3 8 71 200 96 600 5 3 4 8 8 3 4 81 500 111 000 6 8 9 1 8 92 800 126 000 Studs ASTM A193 Grade B7 Nuts ASTM A194 Grade 2H...

Страница 8: ...Phone 440 871 5700 Fax 440 871 9577 Toll Free 1 800 848 3333 www plidco com E mail pipeline plidco com PLIDCO CLAMP RING Plidco Clamp Ring PLIDCO DEPARTMENT 100 at 440 871 5700 toll free U S Canada 8...

Страница 9: ...2 4 Clamp Ring Clamp Ring 3 PLIDCO 5 Z87 6 1 Plidco Clamp Ring 2 Flat Spots 3 4 Ovality Gauge Plidco PLIDCO Ovality Gauge 5 5 6 7...

Страница 10: ...3 1 2 Plidco Clamp Ring SUPERBOLT SUPERBOLT 3 PLIDCO WELD END PLIDCO FLANGE 4 6 Clamp Ring 1 1...

Страница 11: ...4 5 1 4 6 4 6 7 8 1 4 6 4 2 10 50 100 100 BOLT RELAXATION 9 SUPERBOLT SUPERBOLT 2...

Страница 12: ...CLAMP RING Plidco Clamp Ring 1 5 End Restraint PLIDCO 2201 API Procedures for Welding or Hot Tapping on Equipment in Service Section 6 5 10 API API Standard 510 Section 5 8 pressure testing precautio...

Страница 13: ...6 Plidco Clamp Ring Plidco 1 API Standard 510 Section 5 8 pressure testing precautions 4 24 2 3 6 4...

Страница 14: ...8 690 2 1 2 8 3 7 8 8 890 12 000 47 500 psi pre stress 3 2 3 4 8 4 1 4 10 800 14 600 3 8 4 5 8 14 200 19 300 3 1 4 8 5 18 200 24 600 3 1 2 8 5 3 8 22 800 30 900 3 3 4 8 5 3 4 28 100 38 200 4 8 6 1 8 3...

Отзывы: