Operational Manual Plettenberg Motor control MST-60-80 V5.1
S. 11
9
Initial operation of the drive system:
For the first test of the wiring of the drive system, we recommend to use a current limited
power supply. A power supply with an output voltage of 12V will do the job. At the first time
please use only low throttle, if the motor is running rough or only vibrates, put the throttle
back to zero and disconnect the battery cables.
Please check in this case the connection between the controller and the motor. There exist
only 6 combinations to connect the motor phases:
After the MST controller is connected to the battery voltage the controller send on the
RS232-Interface a small short instruction including the actual control parameters:
* Kommandoliste:
* 's' Serieller Sollwert
* 'p' Poti Sollwert
* 'i' Impuls Sollwert
* 'f' Forward
* 'r' Reverse
* '0' Off
* 'b' Brake
* 'm' 100% PWM(max)
* '9' 90% PWM
* '8' 80% PWM
* '7' 70% PWM
* '6' 60% PWM
* '5' 50% PWM
* '4' 40% PWM
* '3' 30% PWM
* '2' 20% PWM
* '1' 10% PWM
* '+' +1% PWM
* '-' -1% PWM
* 'g'+0.1% PWM
* 'l'-0.1% PWM
* 'w' write setup
* 'h' Help
MST60-80
Input = Analog
AnalogStop/Start/Full/BrakeMax = 500mV/ 549mV/4499mV/4499mV
Controller Phase A Controller Phase B Controller Phase C
Motor Phase A
Motor Phase B
Motor Phase C
Motor Phase A
Motor Phase B
Motor Phase C
Motor Phase B
Motor Phase A
Motor Phase A
Motor Phase C
Motor Phase C
Motor Phase B
Motor Phase C
Motor Phase C
Motor Phase B
Motor Phase B
Motor Phase A
Motor Phase A