background image

 

 

Wireless Pro Pace 

Clock and Shot Clock

 

 

 

 

 

 

 

 

 

 

 

 

 

User Guide

 

 

 

 

 

 

 

 

 

 

 

F904 Rev. 202008 

Содержание Colorado Time Systems Pro Pace Clock/Shot Clock

Страница 1: ...Wireless Pro Pace Clock and Shot Clock User Guide F904 Rev 202008 ...

Страница 2: ... Street Loveland CO 80537 USA Sales 800 279 0111 or 1 970 667 1000 Service 1 800 287 0653 or 1 970 667 1000 FAX 970 667 1032 Web www coloradotime com Email support coloradotime com Part Number F904 Rev 202008 2020 Colorado Time Systems All rights reserved ...

Страница 3: ...Operation Connected by Data Cables With Timer or Controller Water Polo Operation 9 Physical Setup 9 Displaying Information 9 Shot time Game time Time out time Team scores Time of day Training Modes 11 Lap counter 11 Simple Pace Clock 12 Pace clock with Cumulative Splits 12 Pace clock with Lap Splits 13 Relay Exchanges 13 Start Reaction 14 Turn Speed 14 Breakout Time 15 Start Reaction and Breakout ...

Страница 4: ... Scoreboard Modes 19 Physical Setup 19 Swimming 19 Lane Times Event Heat Training Pace Clock 20 Lane Times Diving 20 Dive Number and Position Current Round Current Diver Synchronized Swimming 20 Award All Sports 20 Specifications 21 ...

Страница 5: ...bes the training modes including what the mode does and which other devices are needed for the mode Scoreboard Chapter 5 beginning on page 19 describes using a Pro Pace Clock Shot Clock to display additional information The information available for display varies by sport How to Set Intensity Channel and Mode Make sure the antenna is screwed on Use the Mode switch on the front panel to set intens...

Страница 6: ... the same channel NOTE The initial channel displayed will be the last setting saved before the clock was turned off It will not change until the knob is turned for the first time Mode After the Mode switch has been in the same channel setting for 4 seconds the clock will display the firmware revision and then the current mode At this point the Mode switch changes the mode and only the mode until t...

Страница 7: ...s relay platform pushbutton or start system Plug the device s providing the input into the proper connector s on the front panel Most input connections are self explanatory Pushbuttons For all input connectors a pushbutton operated by a human judge may be connected to provide input however some precision in timing will be lost The pace clock records to a hundredth of a second but a human with a pu...

Страница 8: ...ace clock can be mounted on the wall First determine the location for your pace clock It is your responsibility to choose a location where the wall composition or mounting structure can support the 29 lb 13 2 Kg weight of the pace clock Use appropriate mounting hardware for the wall substrate weight of the clock and its environment The keyhole slots in the back of the clock are 359 inches at the b...

Страница 9: ...e The upper two data cable connections are round 4 pin connectors for RS 485 the lower two are quarter inch phono connectors for RS 232 AC Power connection The power receptacle accepts a standard power cord for 110 VAC If 220 VAC is required the power supply can be modified at the factory Modified units are labeled accordingly ...

Страница 10: ...et the channel to the same channel as the first clock Set the Mode switch to 1 Within 5 seconds the pace clock s will be synchronized to the first clock Connected by Data Cables To run a series of pace clocks connected by cables without an external controller set the Scoreboard Training switch on the front panel of the first pace clock to Training and set the Mode switch to 2 Set the other pace cl...

Страница 11: ... type of data cable Each clock will display the information based on its mode setting a series of connected clocks will display different information from one another if they are set to different mode settings Clocks can also receive information from a System 6 with a wireless adapter please see the wireless adapter manual for details Displaying Information Clocks can be used to display shot time ...

Страница 12: ... be set to display Scoreboard Channel 12 time out time on Module 05 On this clock set the Mode switch to 5 The CTS timer will automatically start and stop the time out clock Team scores To display team scores the CTS timer must be set to display Scoreboard Channel 5 team scores on Module 0D On this clock set the Mode switch to 12 The CTS timer will automatically display and update the team scores ...

Страница 13: ...tart Reaction and Breakout Time 15 10 11 12 13 14 Single Lane Timer 1 2 3 4 or multiple laps 16 15 Mid race Timer 17 16 Test Mode 18 Lap counter Mode 1 Equipment required Touchpad required start system or pushbutton can be used to reset the clock Set up Connect the touchpad to either Touchpad input If using a start system or pushbutton for resetting the display connect the start system or a pushbu...

Страница 14: ...rt input or a double click from the reset input will reset and start the clock Pace clock with Cumulative Splits Mode 3 Equipment required Touchpad required start system or pushbutton can be used to reset the clock Set up If using a start system or pushbutton for resetting the clock connect the start system or a pushbutton to the Start System input or connect a pushbutton to the Reset Breakout inp...

Страница 15: ...t input or a double click from the reset input will reset and start the clock any time the running time is displayed Relay Exchanges Mode 5 Equipment required Touchpad and relay judging platform RJP Set up Connect the touchpad to either Touchpad input Connect the RJP to the Relay Platform input Operation The clock displays 05 indicating mode 5 The numbers on the display go blank leaving the colon ...

Страница 16: ...uring this time are recorded and the last one recorded is displayed at the end of the 2 second window The start reaction time the difference between the start input and the swimmer s departure is displayed until the clock is reset with a double click from the Reset Breakout input or a new start input If a start input is received and no RJP or touchpad input is detected within 2 seconds the clock w...

Страница 17: ...ment required Start system breakout timer or pushbutton and touchpad or relay platform Set up Connect the start system to the Start System input and connect the pushbutton or other breakout timer to the Reset Breakout input Connect the touchpad to either Touchpad input or connect the RJP to the Relay Platform input Operation The clock displays 09 indicating mode 9 The numbers on the display go bla...

Страница 18: ... the clock and the display counts up in seconds Single Lane Timing Start Reaction The first option in all five modes is start reaction time All touchpad or RJP inputs detected during the initial 2 seconds from start input are recorded and the last one recorded is displayed at the end of the 2 second window The start reaction time the difference between the start input and the swimmer s departure i...

Страница 19: ...chpad hit This final time is displayed until a reset or a new start input is detected Relay Exchange Timing All Single Lane Timing Modes with multiple laps or lengths if length timing is being done have optional relay exchange timing capabilities at each touchpad hit before the final one The first touchpad hit cumulative split is recorded disabling the touchpad and starting a 2 second window Durin...

Страница 20: ...mmer to exit the pad The clock records the next touchpad hits The last one recorded push off is compared with the initial touchpad touch and the difference between the two is displayed With a touchpad at one end this is the time it took the swimmer to make an initial turn swim down the lane turn at the other end swim back and complete the turn at the end with the touchpad With a touchpad at each e...

Страница 21: ... phono connector RS 232 whichever your timer or controller supports If you are connecting multiple pace clocks connect the pace clocks to each other with the same type of data cable Each clock will display the information based on its mode setting a series of connected clocks can display different information from one another if they are set to different mode settings Clocks can also receive infor...

Страница 22: ...iver Mode 14 Connect the clock s to a CTS timer running Diving software When a clock is switched to mode 14 it will briefly display r d for Round and Diver It will then display the current round number on the left two digits and the current diver number on the right two digits This mode is helpful for large meets so that divers who may not be able to see the main scoreboard easily can still see th...

Страница 23: ...y with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However ...

Страница 24: ...Customer Service Department www coloradotime com Email support coloradotime com Phone 1 970 667 1000 Toll Free U S and Canada 800 287 0653 Fax 1 970 667 1032 ...