background image

Voice, Data and Video Tester

outlined

Coax Type 

Belden P/N   Shield  Maximum Length

RG-58A/U 

8259 

14.9

Ω

 / 1,000 ft 

6,710ft (2,045m)

 

9311 

25.8

Ω

 / 1,000ft 

3,876ft (1,182m)

 

7806A 

11.8

Ω

 / 1,000ft 

8,475ft (2,583m)

RG-59/U 

9310 

24.1

Ω

 / 1,000ft 

4,150ft (1,265m)

 

9259 

23.5

Ω

 / 1,000ft 

4,255ft (1,297m)

 

8241A 

49.7

Ω

 / 1,000ft 

2,010ft (613m)

 

9275 

78.5

Ω

 / 1,000 

1,275ft (389m)

 

9659 

17.6

Ω

 / 1,000ft 

5,682ft (1,732m)

RG-6/U 

1694A 

7.2

Ω

 / 1,000ft 

13,889ft (4,234m)

 

1152A 

29.8

Ω

 / 1,000ft 

3,360ft (1,025m)

Mini Coax 

9221 

111

Ω

 / 1,000ft 

900ft (275m)

RG-11/U 

1523A 

15.1

Ω

 / 1,000ft 

6,623ft (2,019m)

U SA

MA

DE I

N THE

M

AD

E IN THE US

A

www.platinumtools.com

©2011 Platinum Tools Inc. All rights reserved. 1/11

®

Instruction Sheet: P/N T119

GENERAL SPECIFICATIONS

The Platinum Tools, VDV MapMaster™ is a portable voice-data-video 

cable tester. It tests and troubleshoots RJ11, RJ12, RJ45 and F-conector 

terminated cables and provides built-in tone generation for cable tracing.

• 

Dimensions:

 6.4˝ x 2.8˝ x 1.4˝ (16.3 x 7.1 x 3.6 cm)

• 

Weight:

 9.0 oz. (256 grams) with battery and remote

• 

Operating Temperature:

 0˚C/32˚F to 50˚C/122˚F

• 

Humidity:

 10% to 90%, non-condensing

• 

Maximum Voltage

 between any two connector pins without damage:

    RJ Jack: 66V DC or 55V AC

    F-Connector: 50V DC or AC

• 

Battery Life:

 9V alkaline battery typical

    Standby: 4 years

    Active: 425 hours

• 

Cable Types:

 Shielded or Unshielded; Cat7, Cat6x, Cat5e, 

  Cat5, Cat4, Cat3, Coax

• 

Maximum RJ Cable Length:

 0 to 1,000 feet (305 meters)

• 

Minimum Cable Length for Split Pair Detection:

 

  1.5 feet (0.5 meters)

• 

Maximum Coax Cable Length:

BATTERY REPLACEMENT

1) 

Remove single screw

 in the middle of the back    

    of the VDV MapMaster™ with a #1 Phillips head  

 

    screwdriver. Remove the battery door.
2) 

Remove the old battery

 and disconnect 

    battery cable.
3) 

Replace with an ANSI 1604A

, 9 volt alkaline  

 

    battery (Energizer 522, Duracell Mn1604). Reattach   

    cable and insert into battery compartment.
4) 

Replace battery door

 and screw. 

    DO NOT OVERTIGHTEN!

WARNINGS

To ensure safe operation and service of the tester, follow these instructions. 

Failure to observe these warnings can result in severe injury or death.

• The VDV MapMaster™ is designed for use on unenergized cabling 

  systems. Connecting the VDV MapMaster to live AC power may 

  damage it and pose a safety hazard for the user.

• Poorly terminated RJ plugs have the potential to damage the jacks on the 

  VDV MapMaster™. Visually inspect an RJ plug before inserting it into the 

  tester. The contacts should always be recessed into the plastic housing 

  of the plug. Plugging 6-position plugs into the 8-position jack on the 

  tester has the potential to damage the outermost contacts of the jack 

  unless the plug is specifically designed for that purpose.