27
Section 4.3: User interface examples
The following are examples of how to set target values and other user interface navigation.
Example 1: Put the IBEAM in LOCAL mode and select the Cathode module.
STEP 1)
Press MODE button until LOCAL mode is selected.
STEP 2)
Press MODULE button until Cathode supply is selected.
The red LED for LOCAL and green Cathode supply indicator LED should be ON.
Example 2: Set the beam voltage to 1225 V.
STEP 1)
Press MODULE button until Beam supply indicator LED is ON.
STEP 2)
Use the Control keys to select BV (If IBEAM is in LOCAL mode).
STEP 3)
Use keypad to type 1225, and then ENTER.
Example 3: Set the beam current to 100 mA (IBEAM must be in LOCAL mode).
STEP 1)
Press MODULE button until Beam supply indicator LED is ON.
STEP 2)
Use the Control keys to select BI.
STEP 3)
Use keypad to type 100, and then ENTER.
Example 4: Set the accelerator voltage to 200 V.
STEP 1)
Press MODULE button until Accelerator supply indicator LED is ON.
STEP 2)
Use keypad to type 200, and then ENTER.
Example 5: Set the discharge voltage to 55 V.
STEP 1)
Press MODULE button until Discharge supply indicator LED is ON.
STEP 2)
Use keypad to type 200, and then ENTER.
Example 6: Set the cathode filament current to 2.0 A.
STEP 1)
Press MODULE button until Cathode supply indicator LED is ON.
STEP 2)
Use keypad to type 2.0, and then ENTER.
Example 7: Change the cathode filament current to 2.4 A.
STEP 1)
Press MODULE button until Cathode supply indicator LED is ON.
STEP 2)
Select INC (increment) in the control keys, and press it 4 times.
Example 8: Set the neutralizer filament current to 4.5 A.
STEP 1)
Press MODULE button until Neutralizer supply indicator LED is ON.
STEP 2)
Use keypad to type 4.5, and then ENTER.