Section 4.2: Keypad Entry and Power Supply Adjustments
Adjustments or new target values to the individual power supplies can be input using the keypad. A
CLEAR and ENTER key are provided. In order to select a specific power supply, repeatedly press
the MODULE button. A green LED (supply indicator) will illuminate near the power supply which
indicates parameters for that supply can be entered (see Figure 4.2).
Figure 4.2: Select the supply by pressing the MODULE button until the green LED lights
.
Other global parameters are entered into the CONTROL module. These can be accessed when the
green LED is lighted as shown in Figure 4.3.
Figure 4.3: Global parameter entry. To access, press MODULE button until LED lights
Directly under the main display are 3 control keys. These are used as SELECT buttons for
parameters that are presented in the main display directly above (see Figure 4.4).
Figure4.4. Control keys are used to select options in the main display.