2. Plug the hose of the extraction system into the suction port (2).
3. If you are using another extraction system than that provided by
Planmeca, check that the extraction system is correctly connected.
What to do next
Start the milling process with the extraction system switched on. See section
"Starting milling process" on page 77.
16.8.3 Preparing for wet milling
About this task
CAUTION
The milling unit must only be operated with approved coolant lubricants from
Planmeca. Do not use running water for cooling/lubrication.
CAUTION
Wet processing with this milling unit shall only take place without an
extraction system that is switched on.
Always when wet milling is performed, the extraction system must not be
used. If the extraction system is connected to the milling unit, switch it off
before starting milling and ensure that it does not start during the milling
process.
Generally the following materials are wet-processed using a coolant
lubricant:
•
Lithium disilicate
•
Glass-ceramic
•
Prefabricated titanium abutments
16 Operating milling unit
User's manual
Planmeca PlanMill 60 S 75