Copyright Planika Sp. z o.o.
www.planikafires.com
IG0033#08
2020-03-20
9
Photo 2
•
If all the points were completed according to the instruction the gas bottle can be now
connected (See point 3.4.2).
WARNING
!!! All elements above the fireplace need to be made of non-flammable materials.
•
Select a location where the outdoor fire can be supervised during operation.
•
The outdoor fire is suitable for outdoor use only and must not be used indoors.
•
An isolation switch must be fitted at the appliance or on an adjacent wall to allow for emergency shutdown
and maintenance.
•
Installation must meet Australian gas codes AS/NZS5601.1-2013.
•
Do not install under trees or overhanging branches.
•
Do not install under eaves, overhang or ceilings.
•
Ensure adequate space around the fire to enjoy the flame from a safe distance from the heat and flame.
•
Appliance should be covered or protected in wet weather. Not suitable for use in wet or windy weather.
Only use this appliance in an above ground open air situation with natural ventilation, without stagnant areas, where
gas leakage and products of combustion are rapidly dispersed by wind and natural convection.
Any enclosure in which the appliance is used shall comply with the following:
•
An enclosure with walls on all sides, but at least one permanent opening at ground level and no overhead
cover.
•
Within a partial enclosure that includes an overhead cover and no more than two walls.
•
Within a partial enclosure that includes an overhead cover and more than two walls the following shall
apply.
o
at least 25% of the total wall area is completely open, and
o
at least 30% of the remaining wall area is open and unrestricted
•
In the case of balconies, at least 20% of the total wall area shall be and remain open and unrestricted.
•
This appliance shall not be used or installed indoors.
•
The following figures are diagrammatical representations of outdoor areas