Copyright Planika Sp. z o.o.
www.planikafires.com
IG0033#08
2020-03-20
28
5.
TESTING
WARNING!!!
NEVER TURN ON THE DEVICE IF THE CHARACTERISTIC SMELL OF GAS IS PERCEPTIBLE.
If you smell gas during the operation of the fireplace turn off the device immediately and cut off the gas supply from
the gas cylinder by shutting its valve.
5.1
Checking for gas leaks.
•
Check if all connections are airtight.
•
To do that apply all connections with soapy water (or water with another foamy substance) or with a
professional spray for leak detection.
•
If air-bubbles are present that means the connection has a leak.
•
Remove the leaks in the identified spaces.
•
Check for leaks once again.
•
After the inspection dry the inspected connections.
•
The device may only be used again after all leaks are removed.
•
If the problem happens again please contact the dealer.
5.2
Checking the flame appearance.
•
Burn the GaLiO Corten on max flame height and check the appearance of the flame. Ensure test point pressure
is as per the data plate on the appliance and at the end of this manual.
•
The flame should be linear and evenly placed on the whole length of the main burner.
•
If visible gaps are present or there are substantial differences in flame height turn off the fireplace and after
the device is cooled adjust the placement of decorative stones in such a way for them to be evenly placed on
the whole surface of the main burner.
•
WARNING!!!
Stones must not cover the area between the burner and pilot cover, which houses the ignition
and the pilot flame.
•
Turn on the fireplace and check the appearance of the flame once again.