4.1.
Directions of how to design a cavity for the fireplace
•
When preparing the cavity make sure the surface on which the insert is placed is well-levelled.
•
Bottom surface of the cavity has to be made with min. 5% inclination to lead out water through
Fig. 3
–
Cavity measures for units
4.2.
Installation of glass screens
•
Carefully remove cardboard and foam foil from the glass guards.
•
Remove all contaminations from the glass guards which could burn out on the glass during operation of the
Galaxy Burner (in particular fingerprints).
•
Install glass guards in the corresponding slots on the appliance as shown below
Fig. 4
–
Glass guards installation
•
Remove the glass guards only in case of damage of the glass.
L3
D1
L
L1
L2
D
D2
H4
H
L2
H1
H2
H3
A-A
Ventilation
air
Water
B-B
Surface inclination
min. 5%
Surface inclination
min. 5%
Water
WARNING
Cavity has to be made with ventilation grate located on the lowest point as on below scheme.
It is required for cooling the device and water drainage.