21
6.5.4.
Flame height directly to minimum position
Pressing the
„
-
“
button twice automatically decreases
the flames to the LOW position
NOTE:
Flame goes to high fire first before going to low
fire.
6.5.5.
Flame height directly to maximum position
Pressing the
„+“
button twice automatically increases
the flames to the HIGH position
Press and hold
„+“
button to increase the flame level and
to turn on the burner from the stand-by position.
NOTE:
If you turn on the burner by pressing the button, it
must ignite within 10 seconds. If this does not happen,
immediately close the gas tap and warn the fitter.
6.5.6.
Automatic Turn Down To Pilot
3 Hour No Communication Function
The valve will turn to pilot flame if there is no communication between handset and receiver for a 3 hour period. The
fire will continue to function normally when communication is restored.
Receiver Overheating
•
Powered by mains adapter: The valve turns t
o pilot flame if the receiver temperature is higher than 176 °F
(80 °C). If batteries are installed in the receiver in this configuration the temperature must not exceed 60 °C.
•
Powered by batteries and/or connected to the V module: The valve turns to pilot position if the temperature
in the receiver is higher than 140 °F (60 °C).
NOTE:
When the receiver temperature is below 140 °F (60 °C), the main burner can be turned ON manually.
6.5.7.
Automatic Shut Off
Countdown Timer
At end of countdown time period, the fire shuts off. The Countdown Timer only works in Manual, Thermostatic, and
Eco Modes. Maximum countdown time is 9 hours and 50 minutes.