14
5.3.
Pressure regulator replacement (LPG version)
1.
You always need to use a pressure regulator between the gas cylinder and the device. Replace the pressure
regulator every 5 years. Allowed pressures: 30 mbar, 37 mbar (recommended), 50 mbar. Use only the redactors
that comply with the EN16129 European Norm.
2.
Turn off the Galaxy Burner
–
the „OFF” position. The main burner and the pilot burner need to be turned off.
3.
Disconnect the regulator from the gas cylinder (description above).
4.
Loosen the metal clamp with the use of a
screwdriver (philips) or a flat wrench.
5.
Move the clamp away from the stub of gas
regulator.
6.
Take off the linkage from the stub of regulator.
7.
Attach a new linkage on the stub of regulator.
8.
Move the clamp into the stub again and
tighten it. WARNING! In the event of visible
damage on the clamp, replace it for a new one.
Table 3
–
Pressure regulator replacement