Planex FMX-24P Скачать руководство пользователя страница 1

 

 

Содержание FMX-24P

Страница 1: ......

Страница 2: ...anaging the Switch 8 3 1 Serial Port Connection 8 3 2 Telnet Connection 9 4 Configuring the Switch 10 4 1 Logging into the Switch 10 4 2 Menu Hierarchy 10 4 2 1 Configuration 12 4 2 2 Network Monitoring 45 4 2 3 SNMP Manager Configuration 53 4 2 4 User Accounts Management 54 4 2 5 System Utilities 55 4 2 6 Save Changes 61 4 2 7 Reboot 62 4 2 8 Logout 63 5 Sample Configuration 64 5 1 Configuring IP...

Страница 3: ... Telnet and RS 232C console connection Furthermore its built in RMON based network monitoring function reduces the burden on your system administrator as it enables him her to remotely monitor the communication status Product Features z IEEE802 3af compliant power supply feature provides a total and maximum of 152W for the 24 ports z Complies with IEEE802 3 10BASE T and IEEE802 3u 100BASE TX stand...

Страница 4: ...s x2 z Rackmount setscrews x8 z Rubber footpads x4 z This user s manual CD ROM z Warranty card If any item is found missing please contact your local retailer or our technical support 1 3 Part Names Front Panel 1 RJ 45 STP Connector Each connector represents an RJ 45 port to which a 10BASE T 100BASE TX twisted pair cable attaches 2 Serial Port The supplied RS 232C cable connects to this D SUB 9pin...

Страница 5: ...tional status of each port LED Status Description Green ON The LED is turned on when there is a 100M link Green Blinking The LED flashes during 100M data transfer Orange ON The LED is turned on when there is a 10M link Orange Blinking The LED flashes during 10M data transfer Link Act OFF The LED is dark when there is no link on the port Green ON The LED is turned on when there is link in full dupl...

Страница 6: ... 2 Cautionary Notes on Selecting Installation Location Please strictly follow the instructions below when installing the product z Do not install the product in a damp place z Avoid exposure to direct sunshine and or dust z Be sure to allow some space between the product and surrounding walls etc z Do not place any object on the product An accumulation of dust or dirt in the air vents near the fan...

Страница 7: ...ar side of the product 1 Attach the 3 lead plug of the power cable to an outlet with grounding 2 Installation of the power cable is successful if the Power LED system LED is turned on Note that all LED s are turned on immediately after the product is powered During self diagnostics Console LED will flash Data transfer communication starts as soon as Console LED goes off 2 4 Performing Basic Config...

Страница 8: ... the other end of the cable to your hub or network port on your PC 3 The product automatically detects the best network speed for both the switch itself and the target device as long as the target device supports Auto Negotiation 4 If only one of the devices is set to Auto Negotiation and the speed setting of the other device is fixed to a certain speed connection mode is automatically fixed to ha...

Страница 9: ...N settings z Configure Spanning Tree settings z Download system firmware z Upload and download configuration file 3 1 Serial Port Connection The switch can be configured and managed via a computer attached to the serial port on the front panel of the product Serial port based configuration utilizes a VT 100 equivalent terminal utility program Windows 95 98 98SE Me 2000 XP PC utilizes a communicati...

Страница 10: ...ble is D SUB 9pin female female Attach one end of the serial cable to the serial port on the front panel of the switch and attach the other end of the cable to the serial port on your computer 3 2 Telnet Connection The management agent can be started via Telnet as well The factory default management IP address of the product is 10 90 90 90 8 and its Telnet interface has been enabled The agent can ...

Страница 11: ...nfiguration are first saved in NV RAM Then they are written to flash memory to maintain the same configuration after system power off 4 1 Logging into the Switch The following login screen will appear after logging into the switch No user names or passwords are configured prior to product shipment If this is the first time you are logging into the switch it will accept any text string you enter as...

Страница 12: ...Ns Configure Port Mirroring Configure Threshold of Broadcast Multicast DA Unknown Storm Configure Port Security Configure Class of Service Default Priority and Traffic Class Configure DIFFSERV Settings Configure Power Over Lan Settings Network Monitoring Port Utilization Port Error Packets Port Packet Analysis Browse MAC Address Switch History VLAN Status Port Event Latch POL Information SNMP Mana...

Страница 13: ...onfigure the switch 4 2 1 1 Configure IP Address From the root menu select Configuration Configure IP Address to move to the screen below This option is used to set an IP address to the switch The FMX 24P is an intelligent switching hub and it utilizes this IP address to enable SNMP traps and Telnet based remote management An IP address must be reconfigured before adding FMX 24P to an existing net...

Страница 14: ...OOTP IP address is automatically obtained from BOOTP DHCP IP address is automatically obtained via DHCP Factory default Manual 2 IP Address Displays the IP address currently in use 3 Subnet Mask Displays the subnet mask currently in use 4 Default Gateway Displays the default route currently in use 5 Management VID Displays the management VID currently in use New Switch IP Settings This option is u...

Страница 15: ... configuration Invalid entry will be ignored and the factory default is 255 0 0 0 4 Default Gateway This option specifies the address of a default route that is used to remotely configure and manage the switch from a separate network Enter 0 0 0 0 if you do not wish to use a default gateway For this option the switch will not check for invalid entries 5 Management VID This option defines the manag...

Страница 16: ...rmation This option displays various data of the switch System name and location setting for SNMP management can be configured via this option 2 Configure Advanced Switch Features The storage time of MAC addresses and other advanced configuration settings of the system can be configured through this option Switch Information This option displays product information 1 Device Type Indicates device t...

Страница 17: ...haracters maximum to specify the system location of the product 8 System Contact Enter an alphanumeric string 256 characters maximum to specify the system contact of the product 9 APPLY Use this option to store the current configuration to DRAM Select APPLY to modify and update the configuration of the switch that is currently running 10 ADVANCED SETTINGS Select this option to enable the Advanced ...

Страница 18: ...ng Time sec This option is used to specify the duration for which dynamically learned MAC addresses are retained A value between 10 and 1 000 000 sec may be selected and the factory default is 300 sec It is strongly recommended NOT to change this parameter unless there is a specific reason to do so 3 Switch GVRP The product does not support this feature 4 Telnet Status Enables or disables Telnet b...

Страница 19: ...orted via CoS Available options are Strict and Round Robin and the factory default is Strict Select Strict if no delay is allowed ex IP telephony applications etc 8 Backpressure The product does not support this feature 9 POL State Disables or enables the power supply function The factory default is Enabled 4 2 1 3 Configure Port From the root menu select Configuration Configure Ports to move to t...

Страница 20: ...t speed please make sure that the port speed of the target network device is fixed as well If a port with automatic speed detection setting is connected to a port with a fixed speed half duplex mode is used on the port with auto speed detect setting The FDX LED of the port on the front panel will be turned on if full duplex mode is selected If a specific port speed other than Auto has been set to ...

Страница 21: ... Value Since the flow control function is not available yet this item shows Speed Disabled 4 Connection Indicates the current link status Ports with no link are indicated by the minus sign 4 2 1 4 Configure Bandwidth From the root menu select Configuration Configure Bandwidth to move to the following screen This screen allows the user to specify bandwidth for each port This screen option consists ...

Страница 22: ...the port 1 Action Select either Add Modify or Delete to add modify or delete the port specified in the next option see below 2 Port Enter the port you wish to add modify or delete 3 Ingress Bandwidth Enter a value between 1 and 127 unit to specify the actual bandwidth 4 APPLY Use this option to store the current configuration to DRAM Select APPLY to modify and update the configuration of the switc...

Страница 23: ...en configured for the port 3 Kbytes Converts the number of units to KByte This is the value that is actually used in the configuration 4 Port Speed Displays the link status of the port being configured If there is no link it will show none If the port speed has been fixed to a certain value the corresponding speed will be displayed even if there is no link on the port Configure Port Egress Bandwid...

Страница 24: ...tore the current configuration to DRAM Select APPLY to modify and update the configuration of the switch that is currently running 1 unit 125KB Although the actual upper limit is 100Mbps for 100 units the configuration screen displays 127 units 127Mbps Changes made to the existing configuration will be displayed in the screen 4 2 1 5 Configure Spanning Tree Protocol From the root menu select Confi...

Страница 25: ...ion time used in Spanning Tree A value between 1 and 10 seconds may be entered and the factory default is 2 sec 4 Forward Delay Use this option to specify the forward delay time used in Spanning Tree A value between 4 and 30 seconds may be entered and the factory default is 15 seconds 5 Priority Use this option to specify bridging priority When combined with the switch s MAC address bridging prior...

Страница 26: ...be modified only by users who have a good understanding of STP technology or the entire network may be disabled The factory default timer settings are the values most appropriate for networks up to the size of seven lines permitted by IEEE Also note that the following STP parameters may not be modified transit delay 1 sec bpdu delay 1 sec msg overestimate 1 sec lost msg 3 TX halt delay 1 sec Med a...

Страница 27: ...tatus This option is used to enable disable Spanning Tree function The factory default is Disable 4 Cost This option is used to specify port cost The factory default is 19 and recommended port cost values are as follows 100MFDX 19 100MHFX 18 10MFDX 95 10MHFX 100 5 Enter a value between 0 and 255 as port priority The factory default is 128 6 ByPass This option is used when the port is used as fast ...

Страница 28: ...s Spanning Tree status 4 Cost Displays the cost assigned to the selected port 5 Priority Indicates port priority 6 ByPass Displays the status of Fast Forward function 7 Port States Indicates the current Spanning Tree status of the port Disabled There is no cable link on the port Listening Indicates the Spanning Tree Listening state and data communication cannot take place in this state Learning In...

Страница 29: ...ion Address Filtering Table to move to the following screen This screen is used to add MAC addresses and configure MAC address filtering The screen consists of two levels 1 Configure Static Unicast Filtering Table This option is used to manually configure assign MAC addresses to each port 2 Configure Static Multicast Filtering Table This option is used to manually configure assign multicast addres...

Страница 30: ... associated with the MAC address VLAN or port number configured Select Permanent to let the switch learn addresses statically or select Delete on Reset to filter out the registered address 4 MAC Address Enter the MAC address you wish to configure 5 Allow to Go Port Enter the number of port you wish to configure 6 APPLY Use this option to store the current configuration to DRAM Select APPLY to modi...

Страница 31: ...bers that have been registered to the switch 5 Type Displays the action associated with the registered addresses Configure Static Multicast Filtering Table This option is used to manually associate MAC addresses and multicast MAC addresses to the switch The configuration method is the same as Configure Static Unicast Filtering Table You may not dynamically assign configure learned addresses Before...

Страница 32: ...f three levels 1 Configure Static VLAN Entry This option is used to add a VLAN group and assign each VLAN group to a specific port 2 Configure Port VLAN ID Use this option to configure the Port VLAN ID of each port 3 Configure Port Ingress Filter Use this option to enable disable Ingress Filter of each port Configure Static VLAN Entry This option is used to both create a VLAN group and assign each...

Страница 33: ... added to a VLAN group Use for ports that are not member of the group 4 Tag UnTag This option is used to determine whether Tag transmission or UnTag transmission is made when a port transmits frames with VLAN information Enter T for Tag transmission or U to perform UnTag transmission 5 State Use this option to configure the status of the VLAN being configured 6 APPLY Use this option to store the c...

Страница 34: ...e this option to specify the range of port numbers that you wish to configure 2 PVID Specify a PVID number for the port that have been selected via Configure Port from 3 APPLY Use this option to store the current configuration to DRAM Select APPLY to modify and update the configuration of the switch that is currently running Configure Port Ingress Filter Use this option to configure Ingress Filter...

Страница 35: ... Filter on the ports specified via Configure Port from 3 APPLY Use this option to store the current configuration to DRAM Select APPLY to modify and update the configuration of the switch that is currently running 4 2 1 8 Configure Port Mirroring From the root menu select Configuration Configure Port Mirroring to move to the following screen This screen is used configure port mirroring settings ...

Страница 36: ...get Port Use this option to specify the port to which the frames duplicated via mirroring function are sent Sniffer port 4 Mirror Status Use this option to enable or disable port mirroring 5 APPLY Use this option to store the current configuration to DRAM Select APPLY to modify and update the configuration of the switch that is currently running 4 2 1 9 Configure Threshold of Broadcast Multicast D...

Страница 37: ... Use this option to enable disable the function for monitoring other storms 4 Threshold Pkts sec Use this option to specify the maximum number of packets allowed in one second for the monitoring function Enter a value between 0 and 262143 5 APPLY Use this option to store the current configuration to DRAM Select APPLY to modify and update the configuration of the switch that is currently running 4 ...

Страница 38: ...this option to specify the upper limit of the number of MAC addresses learned by a single port Enter a value between 0 and 10 5 Mode Use this option to specify the method by which MAC addresses are learned DeleteOnReset Select this option to delete MAC addresses immediately DeleteOnTimeout Select this option to let the entries be deleted after the aging time of MAC address table has expired APPLY ...

Страница 39: ...vice Use this option to specify latency and the number of packets in packet transmission queue that is used for the round robin method 2 Configure Default Priority Use this option to specify the CoS value for each port CoS value is assigned to frames received that do not include CoS information 3 Configure Class of Traffic Based on the CoS value one of the four Classes used by the switch is assign...

Страница 40: ...or which packets received via the round robin method are retained not destroyed Enter a value between 1 and 255 where 1 equals 16m sec 3 APPLY Use this option to store the current configuration to DRAM Select APPLY to modify and update the configuration of the switch that is currently running Configure Default Priority Use this option to specify the CoS value for each port CoS is assigned to incom...

Страница 41: ...on to specify the CoS value assigned to the ports selected via Configure Port From above 3 APPLY Use this option to store the current configuration to DRAM Select APPLY to modify and update the configuration of the switch that is currently running Configure Class of Traffic Use this option to modify the four class types used by this product that are assigned to CoS values ...

Страница 42: ... APPLY Use this option to store the current configuration to DRAM Select APPLY to modify and update the configuration of the switch that is currently running 4 2 1 12 Configure DIFFSERV Settings From the root menu select Configuration Configure DIFFSERV Settings to move to the following screen This screen is used to configure DIFFSERV settings ...

Страница 43: ...l be used if DSCP value is zero DSCP value Enter the DSCP value you wish to configure TOS TOS will be used Mode Force Overwrite TOS value is overwritten with the value entered here TOS Overwrite 802 1p TOS priority value is checked and is overwritten with CoS value 802 1p Overwrite TOS CoS priority value is checked and is overwritten with TOS value TOS Value Enter the TOS value you wish to configu...

Страница 44: ...creen This screen is used to configure power supply function The screen consists of two levels 1 Configure Power Ports Use this option to enable or disable power supply function on ports 2 Configure POL Functionality Control Use this option to enable or disable the power supply function of the product Configure Power Ports Use this option to enable or disable power supply function on each port ...

Страница 45: ...numbers available 3 Admin State Use this option to enable or disable power supply function on the ports specified via Configure Port from above 4 APPLY Use this option to store the current configuration to DRAM Select APPLY to modify and update the configuration of the switch that is currently running Configure POL Functionality Control This option is used to enable or disable the function to dete...

Страница 46: ... to IEEE802 3af standard 4 2 2 Network Monitoring This option is used to display various information of the product 4 2 2 1 Port Utilization From the root menu select Network Monitoring Port Utilization to move to the following screen This screen is used to display the port utilization status of the product ...

Страница 47: ...ackets sent from the port in PPS 5 RX Pkts sec Displays the number of packets received by the port in PPS 6 Util Displays the utilization rate of port bandwidth in Bandwidth utilization rate reflects the sum of both transmission and reception of packets 4 2 2 2 Port Error Packets From the root menu select Network Monitoring Port Error Packets to move to the following screen This screen is used to ...

Страница 48: ...ation 2 CLEAR COUNTER Use this option to clear the counter 3 Interval Use this option to specify the interval at which the information is updated 4 2 2 3 Port Packet Analysis From the root menu select Network Monitoring Port Packet Analysis to move to the following screen This screen displays the number of packets received and sent by the product ...

Страница 49: ...TER Use this option to clear the counter 3 Interval Use this option to specify the interval at which the information is updated 4 2 2 4 Browse MAC Address From the root menu select Network Monitoring Browse MAC Address to move to the following screen This screen displays the MAC address table that stores the MAC addresses learned by the switch ...

Страница 50: ... MAC addresses ALL Select this item to display all addresses Port Select this item to display the MAC addresses learned by the specified port number 4 2 2 5 Switch History From the root menu select Network Monitoring Switch History to move to the following screen This screen is used to display switch history The displayed information will be cleared when the switch is turned off or rebooted 1 Seq ...

Страница 51: ...on for only one VLAN ID is shown at a time and VLAN IDs are displayed in increasing order Press Ctrl N to move to the next VLAN ID 1 Number of IEEE802 1Q VLAN Indicates the total number of VLAN s currently configured 2 IEEE802 1Q VLAN ID Displays the VLAN ID of the VLAN information currently displayed 3 Current Egress Ports Indicates the ports that belong to this VLAN 4 Current Untagged Ports Disp...

Страница 52: ...2 7 Port Event Latch From the root menu select Network Monitoring Port Event Latch to move to the following screen 4 2 2 8 Power Ports Status From the root menu select Network Monitoring Power Ports Status to move to the following screen This screen is used to view the power supply status of each port Power ports status of twelve ports is displayed at one time ...

Страница 53: ...power ports 6 Status The data indicates whether or not the power supply function is currently in use 7 Cause Port status is displayed under this item Port admin state is OFF The port s PoE status is off Under software detection The PoE status of the port is ON but PoE powered device is not connected Legal PD resistor detection Power is being supplied to a PoE powered device via PoE The maximum cur...

Страница 54: ... Please note that the total and maximum power supplied to all ports via POL is 152W or less 4 2 3 SNMP Manager Configuration Use this option to configure SNMP parameters 1 SNMP Community String Select this option to specify an SNMP community name Prior to shipment two community names public private have been already configured Up to twenty alphanumeric characters may be used for a community name ...

Страница 55: ...ermitted Once an entry is made access requests from unregistered addresses will be rejected 6 APPLY Use this option to store the current configuration to NV RAM Select APPLY to modify and update the configuration of the switch that is currently running 4 2 4 User Accounts Management Use this option to configure user names and passwords Up to eight users may be created If no user names or passwords...

Страница 56: ...ured Root Grants access to all configuration information User Grants permission to both view configuration and restart the system User Grants permission to view configuration At least one user with the Root access needs to be configured at any time 4 2 5 System Utilities Select this option to update firmware and export import system configuration Since the product supports TFTP client function the...

Страница 57: ...ile that has been previously saved to an external TFTP server 3 Save Settings to TFTP Server Use this option to save configuration to an external TFTP server 4 Save History Log to TFTP Server Select this option to save switch history to an external TFTP server 5 Ping Test Select this option to test whether a specific network location is reachable Upgrade Firmware from TFTP Server This option is us...

Страница 58: ...ame of firmware 3 START This option initiates the specified action access to the TFTP server 4 APPLY Use this option to store the current configuration to DRAM Select APPLY to modify and update the configuration of the switch that is currently running Use Configuration File on TFTP Server Select this option to restore a configuration file that has been saved to an external TFTP server ...

Страница 59: ...ile that has been saved on the TFTP server 3 START Select this option to initiate the specified action access to the TFTP server 4 APPLY Use this option to store the current configuration to DRAM Select APPLY to modify and update the configuration of the switch that is currently running Save Settings to TFTP Server Select this option to save the current configuration of the switch to an external T...

Страница 60: ...e to save the current configuration 3 START Select this option to initiate the specified access action to the TFTP server 4 APPLY Use this option to store the current configuration to DRAM Select APPLY to modify and update the configuration of the switch that is currently running Save History Log to TFTP Server Select this option to save the switch history to an external TFTP server ...

Страница 61: ...r a file name to save switch history 3 START Select this option to initiate the specified action access to the TFTP server 4 APPLY Use this option to store the current configuration to DRAM Select APPLY to modify and update the configuration of the switch that is currently running Ping Test Select this option to perform a communications PING test to a specific IP address ...

Страница 62: ... you wish to perform the PING test Enter a value between 0 and 255 3 Start Select this option to initiate the PING test The result of PING tests will be displayed in the same screen 4 2 6 Save Changes Select this option to save the current switch configuration to NV RAM The saved configuration data will be restored when the switch is turned on the next time ...

Страница 63: ...tinue message appears 4 2 7 Reboot Select this option to reboot the switch Only users with ADMIN or USER access right are allowed to execute this action 1 Reboot Select this option to reboot the switch 2 Save Configuration Reboot The switch will reboot itself after saving the current configuration data to NV RAM ...

Страница 64: ...ring the factory default configuration 4 Reboot Load Factory Default Configuration Except IP Address The switch will reboot itself after restoring factory default settings except the current IP address settings Current IP configuration is retained after system reboot 4 2 8 Logout Select this option to log off from the management screen ...

Страница 65: ...ble of providing power to network devices supporting IEEE802 3af PoE through a single network cable In this configuration multiple FMX 24P s are used in the same network The IP address of each FMX 24P needs to be modified before attaching it to the network The management user name and password are modified This configuration utilizes Spanning Tree STP Before attaching the switch to a network its S...

Страница 66: ... 5 1 Configuring IP address This section provides a sample procedure to assign an IP address to the FMX 24P In this example a network with IP address 192 168 1 0 24 is used The IP addresses for the switches are as follows FMX 24P A 192 168 1 252 FMX 24P B 192 168 1 253 FMX 24P C 192 168 1 254 To assign the IP addresses above select Configuration Configure IP Address from the root menu 1 Get IP Fro...

Страница 67: ...er these parameters have been configured Once IP address configuration is complete the new IP configuration is displayed as Current Switch IP Settings in the upper section of the screen Sample Configuration FMX 24P A 5 2 Configuring User Name This section illustrates a sample procedure for configuring a password for managing the switch In this example planex is used as user name while poe is used ...

Страница 68: ...Password poe is used for this configuration 4 Confirm New Password Enter the same password to confirm the correct password 5 Access Level Root is selected in this configuration After all the parameters above have been configured select APPLY Once the configuration is complete the new user account information will be displayed under Current Accounts in the lower section of the screen ...

Страница 69: ...ample FMX 24P B is used as a root bridge while the ports linking FMX 24P A and FMX 24P C are set to blocking state Perform the following steps on all the three FMX 24P s All ports except the ones used to connect to another switch need to be configured as Fast Port To enable the Fast Port configuration select Configuration Configure Spanning Tree Protocol Port Settings from the root menu 1 View Por...

Страница 70: ...er is not changed in this example 5 Priority The parameter is not changed in this example After all the parameters above have been configured select APPLY The new configuration will be displayed in the lower section of the screen Next Spanning Tree needs to be enabled on the switch To enable or disable Spanning Tree select Configuration Configure Spanning Tree Protocol from the root menu ...

Страница 71: ...er all the parameters have been configured select APPLY Perform the following steps on the root bridge This section presents configuration steps for the FMX 24P that serves as a root bridge In Spanning Tree switch with the lowest bridge ID is recognized as the root bridge In this example the priority value of FMX 24P B is set to 100 To change bridging priority select Configuration Configure Spanni...

Страница 72: ...re switch 2 Enable PoE function on each port In this example PoE function is enabled on Port 1 through 22 for all the three units of FMX 24P To enable PoE over the entire switch select Configuration Configure Switch Information and Advanced Settings ADVANCED SETTINGS from the root menu The factory default setting of this option is Enabled Next select Configuration Configure Power Over Lan Settings...

Страница 73: ...his example PoE is enabled on Ports 1 through 22 2 Configure Port from Select the range of ports you wish to configure 3 Admin State Enable or disable PoE on the selected port After all the parameters have been configured select APPLY The new configuration will appear in the lower section of the screen ...

Страница 74: ...em Name FMX 24P A FMX 24P B FMX 24P C System Location Access System Contact PowerLAN To configure SNMP community and other parameters select SNMP Manager Configuration from the root menu 1 SNMP Community String This option is used to configure a community name In this example the two factory default community strings public private are deleted and a new community string planex is added 2 SNMP Trap...

Страница 75: ...m Location and System Contact To set these parameters select Configuration Configure Switch Information and Advanced Settings from the root menu After all the parameters above have been configured select APPLY 5 6 Configuring QoS This last section provides information on configuring QoS parameters on the switch An IP phone is usually equipped with switching functionality The FMX 24P ...

Страница 76: ...ies depending on the QoS functionality provided by the IP phone This example assumes that TOS priority values are attached only to data from IP phone the remaining data do not contain TOS values The configuration procedure consists of the following two steps 1 Select priority control method 2 Configure TOS and CoS To select a priority control method select Configuration Configure Switch Informatio...

Страница 77: ...s configuration to assign TOS values to CoS values To configure TOS select Configuration Configure DIFFSERV Settings from the root menu Change Diffserv setting to TOS Change Mode setting to TOS Overwrite 802 1p After all the parameters have been configured select APPLY ...

Страница 78: ...FMX 24P USER S MANUAL 77 PLANEX COMMUNICATIONS INC Finally save configuration to NV RAM and connect network devices to the product ...

Отзывы: