User’s Manual of WGSD-1022/WGSD-8000
- 281 –
startup direction
— The alarm that may be sent when this entry is first set to valid. If the first sample (after this entry
becomes valid) is greater than or equal to the
rthreshold
, and
direction
is equal to
rising
or
rising-falling
, then a single
rising alarm is generated. If the first sample (after this entry becomes valid) is less than or equal to the
fthreshold
, and
direction
is equal to
falling
or
rising-falling
, then a single falling alarm is generated.
owner name
— Enter a name that specifies who configured this alarm. If unspecified, the name is an empty string.
Default Configuration
The following parameters have the following default values:
type type
— If unspecified, the type is
absolute
.
startup direction
— If unspecified, the startup direction is
rising-falling
.
Command Mode
Global Configuration mode
User Guidelines
There are no user guidelines for this command.
Example
The following example configures the following alarm conditions:
Alarm index — 1000
Variable identifier — abc
Sample interval — 360000 seconds
Rising threshold — 1000000
Falling threshold — 1000000
Rising threshold event index — 10
Falling threshold event index — 20
Console (config)#
rmon alarm
1000 abc 360000 1000000 1000000 10 20
5.19.6 show rmon alarm-table
The
show rmon alarm-table
user EXEC command displays the alarms summary table.
Syntax
show rmon alarm-table
Default Configuration
This command has no default configuration.
Содержание WGSD-1022
Страница 136: ...User s Manual of WGSD 1022 WGSD 8000 136 ...
Страница 152: ...User s Manual of WGSD 1022 WGSD 8000 152 Figure 4 82 Flash Logs screen ...