Planet Power over Ethernet Splitter POE-152S-12V Скачать руководство пользователя страница 1

 

- 1 - 

 

 
 
 
 

 

IEEE 802.3af 

Power over Ethernet Splitter 

 

  

POE-152S-5V/12V 

  

User’s Manual

 

         

 

 

 

 

   

Содержание Power over Ethernet Splitter POE-152S-12V

Страница 1: ...1 IEEE 802 3af Power over Ethernet Splitter POE 152S 5V 12V User s Manual...

Страница 2: ...iate your comments and suggestions FCC Warning This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are des...

Страница 3: ...TION 5 1 5 PRODUCT OUTLOOK 5 2 HARDWARE INSTALLATION 6 2 1 BEFORE INSTALLATION 6 2 2 POE 152 AND POE 152S THE IEEE 802 3AF INJECTOR AND SPLITTER INSTALLATION 7 2 3 CONNECT WITH IEEE 802 3AF DEVICES 8...

Страница 4: ...simultaneously The maximum distance between the PSE and POE 152S is 100M With being installed the PSE combines the Ethernet digital data with power over the twisted pair cables as an injector and POE...

Страница 5: ...ble TIA EIA 568 Category 5 5e 6 cable LED indicator 1 x POE ready in use Operating environment 0 50 Degree C 5 90 RH Storage environment 20 70 Degree C 5 90 RH Dimension W x D x H 73 55 24 mm Weight 5...

Страница 6: ...nvironment If there is any issue for your install a networked device where is very difficult to find a power socket for your AC DC adapter the POE 152S can work with POE 152 IEEE 802 3af Power over Et...

Страница 7: ...o the RJ 45 port of remote device 3 Connect proper DC plug from DC OUT of POE 152S to remote device 4 Power on the remote device and the LED indicator on POE 152S will remains on the screen in Figure...

Страница 8: ...nect with an IEEE 802 3af in line power device like Power over Ethernet Switch then connect proper DC plug from DC OUT of POE 152S to remote device The screen in Figure 3 appears Figure 3 Connect to I...

Страница 9: ...end The cable should be an 8 wire UTP Category 5 or above EIA568 cable within 100 meters A cable with only 4 wire short loop or over 100 meters all will affect the power supply 3 Please check the pow...

Страница 10: ...I_DD 6 BI_DB BI_DA 7 BI_DD BI_DC 8 BI_DD BI_DC 10 100Mbps 10 100Base TX RJ 45 Connector pin assignment Contact MDI Media Dependant Interface MDI X Media Dependant Interface Cross 1 Tx transmit Rx rece...

Страница 11: ...g shows the pin allocation and color of straight cable and crossover cable connection Figure A 1 Straight Through and Crossover Cable Please make sure your connected cables are with same pin assignmen...