![Planet POE-1200 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/planet/poe-1200/poe-1200_user-manual_1563334013.webp)
10
Figure 2-7
Network application installation
The PoE Injector Hub supports Data passive mode, that is, even the PoE Injector Hub is manual power off, the data
between
“DATA”
port and
“DATA+PoE”
port can still be transmitted without data loss.
The POE-1200 / POE-2400 Mid-Span Injector Hub doesn’t support Gigabit data rate. The Ethernet
switches or PoE PDs with Gigabit interface will operate at 100Mpbs Full Duplex mode when connect
to the Mid-Span Injector Hub.
2.2.4 Power over Ethernet Powered Device
3~5 watts
Voice over IP phones
Enterprise can install POE VoIP Phone, ATA and other Ethernet/non-Ethernet
end-devices to the central where UPS is installed for un-interrupt power system
and power control system.
6~12 watts
Wireless LAN Access Points
Museum, Sightseeing, Airport, Hotel, Campus, Factory, Warehouse can install
the Access Point any where with no hesitation
10~12 watts
IP Surveillance
Enterprise, Museum, Campus, Hospital, Bank, can install IP Camera without
limits of install location – no need electrician to install AC sockets.
3~12 watts
PoE Splitter
PoE Splitter split the PoE 48V DC over the Ethernet cable into 5/9/12V DC
power output. It frees the device deployment from restrictions due to power
outlet locations, which eliminate the costs for additional AC wiring and reduces
the installation time.
Содержание POE-1200