
User’s Manual of MGSD-10080F
37
■
Digital Input
The digitail input of the Managed Switch can be activated by the external sensor that senses physical changes. These
changes can include intrusion detection or certain physical change in the monitored area. For examples, the external
sensor can be a door switch or an infrared motion detector.
■
Digital Output
The digital output main function is to allow the Managed Switch to trigger external devices, either automatically or by
remote control from a human operator or a software application.
2.1.2 LED Indications
System
LED
Color
Function
PWR
Green
Lights
to indicate that the Switch is powered on by AC input.
DC1
Green
Lights
to indicate that the Switch is powered on by DC1 input.
DC2
Green
Lights
to indicate that the Switch is powered on by DC2 input.
Fault
Green
Lights
to indicate that Switch AC/DC or port has failed.
Ring
Green
Lights
to indicate that
the ERPS Ring has been created successfully.
R.O.
Green
Lights
to indicate that
Switch has been enabled Ring Owner.
Per SFP Interface
LED
Color
Function
1000
LNK/ACT
Green
Lights:
To indicate the link through that port is successfully established with speed
1000Mbps
.
Blink
:
To indicate that the switch is actively sending or receiving data over that port.
Off:
If L100 NK/ACT LED light-> indicate that the port is operating at 100Mbps.
If LNK/ACT LED Off -> indicate that the port is link down.
100
LNK/ACT
Orange
Lights:
To indicate the link through that port is successfully established with speed
100Mbps.
Blink
:
To indicate that the switch is actively sending or receiving data over that port.
Off:
If 1000 LNK/ACT LED light-> indicate that the port is operating at 1000Mbps
If 1000 LNK/ACT LED Off -> indicate that the port is link down.
Per 10/100/1000Base-T Interface
Содержание MGSD-10080F
Страница 1: ...User s Manual of MGSD 10080F 1 ...
Страница 43: ...User s Manual of MGSD 10080F 43 Figure 2 8 Wires DO0 and DO1 to Open Detector ...
Страница 173: ...User s Manual of MGSD 10080F 173 Figure 4 8 2 Multicast Flooding Figure 4 8 3 IGMP Snooping Multicast Stream Control ...
Страница 276: ...User s Manual of MGSD 10080F 276 Figure 4 11 15 Windows 2003 AD Server Setting Path ...
Страница 358: ...User s Manual of MGSD 10080F 358 ...
Страница 488: ...User s Manual of MGSD 10080F 488 Example Disable SMAC mode MGSD 10080F Aggr mode smac disable ...
Страница 554: ...User s Manual of MGSD 10080F 554 Activate the alternate firmware image Syntax Firmware Swap ...
Страница 603: ...User s Manual of MGSD 10080F 603 SMTP Test ...
Страница 616: ...User s Manual of MGSD 10080F 616 Syntax Show STP ...