Planet ISW-504PT Скачать руководство пользователя страница 1

5-Port 10/100Mbps with 4-Port PoE

Industrial Fast Ethernet Switch

ISW-504PT / ISW-514PT / ISW-514PT15 / ISW-514PTF

User's Manual

Содержание ISW-504PT

Страница 1: ...5 Port 10 100Mbps with 4 Port PoE Industrial Fast Ethernet Switch ISW 504PT ISW 514PT ISW 514PT15 ISW 514PTF User s Manual ...

Страница 2: ... ensure that this User s Manual is accurate PLANET disclaims liability for any inaccuracies or omissions that may have occurred Information in this User s Manual is subject to change without notice and does not represent a commitment on the part of PLANET PLANET assumes no responsibility for any inaccuracies that may be contained in this User s Manual PLANET makes no commitment to update or keep c...

Страница 3: ... the interference at his own expense CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures WEEE Warning To avoid the potential effects on the environment and human health as a result of the presence of hazardous substances in electrical and electronic equipment end users of elec...

Страница 4: ...4 Wiring the Power Inputs 14 2 1 5 Wiring the Fault Alarm Contact 15 2 2 Mounting Installation 15 2 2 1 Install DIN Rail Mounting 16 3 Application 18 3 1 Installation Steps 19 4 Switch Operation 20 4 1 Address Table 20 4 2 Learning 20 4 3 Forwarding Filtering 20 4 4 Store and Forward 21 4 5 Auto Negotiation 21 5 Troubleshooting 22 APPENDIX A Networking Connection 23 A 1 Switch s RJ 45 Pin Assignme...

Страница 5: ...1 2 How to Use This Manual This Industrial Fast Ethernet Switch User Manual is structured as follows Chapter 2 Installation The chapter explains the feature functionality and the physical installation of the Industrial Fast Ethernet Switch Chapter 3 Application The chapter explains the Industrial Fast Ethernet Switch application Chapter 4 Switch operation The chapter explains the Industrial Fast E...

Страница 6: ... 15 4 Watts for each PoE port Auto detect powered device PD Circuit protection prevent power interference between ports Remote power feeding up to 100m Layer 2 Features Complies with IEEE 802 3 10Base T IEEE 802 3u 100Base TX 100Base FX Ethernet standard Supports Auto Negotiation 10 100Mbps Half Full Duplex and Auto MDI MDI X High performance Store and Forward architecture Runt CRC filtering elimi...

Страница 7: ...000V DC Ethernet ESD protection 40 to 75 C operating temperature 1 4 Product Specifications Model ISW 504PT ISW 514PT Hardware Specification 10 100Base TX Ports 5 4 100Base FX interface N A 1 IEEE 802 3af PoE ports 4 4 Dimensions W x D x H 135mm x 87 8mm x 56mm Weight 842g Power Requirement 24 or 48V DC Installation DIN Rail Kit and Wall Mount Ear Power over Ethernet PoE Standard IEEE 802 3af Powe...

Страница 8: ...00Base TX Cat 3 4 5 5e 6 UTP cable 100meters max 2 EIA TIA 568 100 ohm STP 100meters max 3 Multi mode optic fiber 62 5 125μm 50 125μm 2km max Standards Conformance Standards Compliance IEEE 802 3 Ethernet IEEE 802 3u Fast Ethernet IEEE 802 3x Full Duplex Flow Control IEEE 802 3af Power over Ethernet Temperature Operating 40 to 75 Degree C Storage 40 to 85 Degree C Humidity Operating 5 90 Storage 5...

Страница 9: ... Kit and Wall Mount Ear Power over Ethernet PoE Standard IEEE 802 3af Power over Ethernet PSE PoE Power Supply Type End Span PoE Power Output 48V DC Per Port 350mA Max 15 4 Watts Power Pin Assignment 1 2 3 6 Switch Specification Switch Processing Scheme Store and Forward Address Table 2K entries Flow Control Back Pressure for Half Duplex IEEE 802 3x Pause Frame for Full Duplex Switch fabric 1Gbps ...

Страница 10: ...p to 220 550m 4 9 125µm single mode cable provides long distance for 10 15 20 30 40 50 60 70 120km Standards Conformance Standards Compliance IEEE 802 3 Ethernet IEEE 802 3u Fast Ethernet IEEE 802 3x Full Duplex Flow Control IEEE 802 3af Power over Ethernet Temperature Operating 40 to 75 Degree Storage 40 to 85 Degree Humidity Operating 5 90 Storage 5 90 Non condensing Regulation Compliance FCC Pa...

Страница 11: ...tance up to 100 meters through the 4 pair Cat 5 5e UTP wire With Data and Power over Ethernet from one unit the ISW 504PT ISW 514PT ISW 514PT15 ISW 514PTF shall reduce cables deployment and eliminates the need for dedicated electrical outlets on the wall ceiling or any unreachable place With 1Gbps internal switching fabric the Industrial Fast Ethernet Switch can handle extremely large amounts of d...

Страница 12: ...ont Panel Figure 2 1 2 2 2 3 show a front panel of Industrial Fast Ethernet Switch Figure 2 1 ISW 504PT front panel Figure 2 2 ISW 514PT 514PT15 front panel Figure 2 3 ISW 514PTF front panel 2 1 2 LED Indicators System LED Color Function P1 Green Indicate the power 1 has power P2 Green Indicate the power 2 has power Fault Green Indicate the either power 1 or power 2 has no power ...

Страница 13: ...sfully established at 100Mbps Blink Indicate that the Switch is actively sending or receiving data over that port PoE Port LED Color Function PoE In Use Orange Indicate the port is providing 48V DC in line power 1 4 ports 2 1 3 Switch Upper Panel The upper panel of the Industrial Fast Ethernet Switch consist one terminal block connector within two DC power inputs Figure 2 4 shows the upper panel o...

Страница 14: ... steps below to insert the power wire 1 Insert positive negative DC power wires into the contacts 1 and 2 for POWER 1 or 5 and 6 for POWER 2 PWR1 DC 24V 48V V1 V1 V2 V2 Fault PWR2 Input V1 V1 V2 V2 2 Tighten the wire clamp screws for preventing the wires from loosing 1 2 3 4 5 6 Power 1 Fault Power 2 Note The wire gauge for the terminal block should be in the range between 12 24 AWG ...

Страница 15: ...e wire gauge for the terminal block should be in the range between 12 24 AWG 2 Alarm relay circuit accepts up to 30V max 3A currents Fault Alarm Contacts The Fault Alarm Contacts are energized CLOSE for normal operation and will OPEN when failure occurs Fault 2 2 Mounting Installation This section describes how to install the Industrial Fast Ethernet Switch and make connections to it Please read t...

Страница 16: ...plication on Industrial Fast Ethernet Switch please refer to following figures to screw the DIN Rail on the Industrial Fast Ethernet Switch To hang the Industrial Fast Ethernet Switch follow the below steps Step 1 Screw the DIN Rail on the Industrial Fast Ethernet Switch 2 1 Step 2 Lightly press the button of DIN Rail into the track Step 3 Check the DIN Rail is tightly on the track ...

Страница 17: ...instructions described below Step 1 Remove the DIN Rail from the Industrial Fast Ethernet Switch loose the screws to remove the DIN Rail Step 2 Place the wall mount plate on the rear panel of the Industrial Fast Ethernet Switch Step 3 Use the screws to screw the wall mount plate on the Industrial Fast Ethernet Switch Step 4 Use the hook holes at the corners of the wall mount plate to hang the Indu...

Страница 18: ...nterprise For instance 4 camera AP can be easily installed around the corner in the company for surveillance demands or build a wireless roaming environment in the offices Without the power socket limitation the switch makes the installation of cameras or WLAN AP more easily and efficiently 400 Watts UPS DC DC 48V DC PWR 2 PoE IP Cam PoE IP Phone PoE VoIP ATA Redundant Power 24 48V DC PWR1 ISW 504...

Страница 19: ...ugh Category 5 cable for Ethernet connection Step 6 Insert one side of Category 5 cables into the Industrial Fast Ethernet Switch Ethernet port RJ 45 port and another side of category 5 cables to the network devices Ethernet port RJ 45 port ex Switch PC or Server The UTP port RJ 45 LED on the Industrial Fast Ethernet Switch will light up when the cable connected with the network device Please refe...

Страница 20: ...future packets 4 3 Forwarding Filtering When one packet comes from some port of the Industrial Fast Ethernet Switch it will also check the destination address besides the source address learning The Industrial Fast Ethernet Switch will lookup the address table for the destination address If not found this packet will be forwarded to all the other ports except the port which this packet comes in An...

Страница 21: ...idth using conventional cabling and adapters Due to the learning function of the Industrial Fast Ethernet Switch the source address and corresponding port number of each incoming and outgoing packet are stored in a routing table This information is subsequently used to filter packets whose destination address is on the same segment as the source address This confines the network traffic to its res...

Страница 22: ...es use a physical or software switch to change duplex modes Auto negotiation may not recognize this type of full duplex setting Why does the Industrial Fast Ethernet Switch not connect to the network Solution 1 Check every port LED on the Industrial Fast Ethernet Switch 2 Try another port on the Industrial Fast Ethernet Switch to make sure the cable is installed properly while make sure the cable ...

Страница 23: ...45 Connector pin assignment Contact MDI Media Dependant Interface MDI X Media Dependant Interface Cross 1 Tx transmit Rx receive 2 Tx transmit Rx receive 3 Rx receive Tx transmit 4 5 Not used 6 Rx receive Tx transmit 7 8 Not used A 2 RJ 45 cable Pin Assignments The standard RJ 45 receptacle connector ...

Страница 24: ...ange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 Brown 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 Brown SIDE 1 SIDE 2 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 Brown 1 White Green 2 Green 3 White Orange 4 Blue 5 White Blue 6 Orange 7 White Brown 8 Brown Figure A 1 Straight Through and Crossover Cable Pleas...