2.2.3 Wall Mount Plate Mounting
To install the Industrial PoE Switch on the wall. Please follow the instructions below.
Step 1:
Remove the DIN-Rail from the Industrial PoE Switch. Use the screwdriver to loose the screws and remove the
DIN-Rail.
Step 2:
Place the wall mount plate on the rear panel of the Industrial PoE Switch.
Step 3:
Use the screwdriver to screw the wall mount plate on the Industrial PoE Switch.
Step 4:
Use the hook holes at the corners of the wall mount plate to hang the Industrial PoE Switch on the wall.
Step 5:
To remove the wall mount plate, reverse steps above.
2.3 Wiring the Power Inputs
The 6-contacts terminal block connector on the top panel of Industrial PoE Switch is used for two DC redundant power
inputs. Please follow the steps to insert the power wire. The PWR1 is 1(-) & 2(+) and PWR2 is 5(-) & 6(+) contact.
Remember:
Tighten the wire-clamp screws for preventing the wires from loosing.
-19 -