Planet IMG-2100T Скачать руководство пользователя страница 1

User’s Manual of IMG-2x00T  Modbus Gateway  Series 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

RS232/RS422/RS485 

Industrial Modbus Gateway 

IMG-2100T / IMG-2105AT   
IMG-2102T / IMG-2102TS 
IMG-2200T / IMG-2400T 

Содержание IMG-2100T

Страница 1: ...User s Manual of IMG 2x00T Modbus Gateway Series 1 RS232 RS422 RS485 Industrial Modbus Gateway IMG 2100T IMG 2105AT IMG 2102T IMG 2102TS IMG 2200T IMG 2400T...

Страница 2: ...FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radi...

Страница 3: ...e Power Inputs 23 2 1 6 Serial Port Pin Define 25 2 1 7 4 pin Terminal Block PIN Assignment 25 2 2 Installing the Modbus Gateway 26 2 2 1 Installation Steps 26 2 2 2 DIN rail Mounting 27 2 2 3 Wall Mo...

Страница 4: ...4 5 2 3 RTU Master mode 52 4 5 2 4 ASCII Slave mode 53 4 5 2 5 ASCII Master mode 54 4 5 3MB COM 54 4 5 4Modbus Config 54 4 5 4 1Router 54 4 5 4 2Mapping 56 4 5 4 3Parameters 58 4 5 5Priority Control...

Страница 5: ...2200T IP30 Industrial 2 Port RS232 RS422 RS485 Modbus Gateway 2 x 10 100TX 40 75 degrees C 2KV isolation IMG 2400T IP40 Industrial 4 Port RS232 RS422 RS485 Modbus Gateway 2 x 10 100TX 40 75 degrees C...

Страница 6: ...omation environment application solution PLANET has announced a first industrial level 1 port RS232 422 485 Modbus Gateway IMG 2x00T a bridge that converts between Modbus TCP IP Protocol and Modbus RT...

Страница 7: ...RJ45 or 100BASE FX Ethernet port It provides a remote web management and telnet Interface for efficient remote network management The IMG 2x00T also provides PLANET Modbus Gateway utility tool and sup...

Страница 8: ...dwide operation with high availability applications Dual Power Input for High Availability Network System The IMG 2x00T series features a strong dual power input system with wide ranging voltages 9V 4...

Страница 9: ...ctions of the IMG 2x00T Series and how to physically install the IMG 2x00T Series Section 3 MODBUS GATEWAY MANAGEMENT The chapter explains how to manage the IMG 2x00T Series in different ways Section...

Страница 10: ...ster mode supports 32 TCP slave connection requests Slave mode supports 32 TCP master connections PLANET Modbus Gateway utility for finding client device on the network PLANET Smart Discovery utility...

Страница 11: ...XON XOFF Signals RS232 TxD RxD RTS CTS DTR DSR DCD GND RS422 Tx Tx Rx Rx GND 4 wire RS485 Tx Tx Rx Rx GND 2 wire RS485 Data A Data B GND Pin Assignment Serial Port 4 pin Terminal Block Operation Mode...

Страница 12: ...l Port Active Power Requirements 9 48V DC 24V AC redundant power with reverse polarity protection 12 48V DC redundant power with polarity reverse protection function Power Consumption Full Loading 9VD...

Страница 13: ...ent Windows based VCOM Utility management SNMPv1 v2c SNMP Trap UNI NMS monitoring PLANET Smart Discovery Utility IP Version IPv4 Operation Mode RTU Master RTU Slave ASCII Master ASCII Slave Virtual CO...

Страница 14: ...rds IEEE 802 3 10BASE T IEEE 802 3u 100BASE TX 100BASE FX RFC 768 UDP RFC 793 TFTP RFC 791 IP RFC 792 ICMP RFC 854 Telnet RFC 958 NTP RFC 1908 SNMPv2c RFC 2068 HTTP RFC 2131 DHCP Client EIA TIA RS232...

Страница 15: ...or rack For easier management and control of the Modbus Gateway familiarize yourself with its display indicators and ports Front panel illustrations in this chapter display the LED indicators Before...

Страница 16: ...User s Manual of IMG 2x00T Modbus Gateway Series 16 IMG 2105AT 32 x 87 x 135 mm W x D x H...

Страница 17: ...User s Manual of IMG 2x00T Modbus Gateway Series 17 IMG 2102T and IMG 2102TS 32 x 87 x 135 mm W x D x H...

Страница 18: ...User s Manual of IMG 2x00T Modbus Gateway Series 18 IMG 2200T 32 x 87 x 135 mm W x D x H...

Страница 19: ...User s Manual of IMG 2x00T Modbus Gateway Series 19 IMG 2400T 56 x 87 x 135 mm W x D x H...

Страница 20: ...T IMG 2102TS IMG 2200T IMG 2400T Figure 2 1 1 Front Panels of Modbus Gateways Fast TP SFP SC interface 10 100BASE TX copper RJ45 twisted pair Up to 100 meters 100BASE FX SFP interface Up to 2km 120km...

Страница 21: ...buzzer The following is the summary table of the reset button functions Reset Button Reset Button Pressed and Released Function System Reset 5 sec System reboot Reboot the Industrial Serial Server 5...

Страница 22: ...er 2 is activated Fault Red Lights Indicates either Power 1 or Power 2 has no power SYS Green Blinks System is booting Lights System is ready I O Red Blinks Digital I O event is triggered 10 100BASE T...

Страница 23: ...sert positive negative DC power wires into Contacts 1 and 2 for Power 1 or Contacts 5 and 6 for Power 2 Figure 2 1 3 to 2 1 5 show PWR1 and PWR2 of the Modbus Gateways IMG 2100T IMG 2105AT IMG 2102T I...

Страница 24: ...Modbus Gateway Series 24 1 2 3 4 5 6 V1 V1 V2 V2 Power 1 Fault Power 2 Figure 2 1 6 PWR1 PWR2 pina of terminal block The wire gauge for the terminal block should be in the range from 12 to 24 AWG 3 DI...

Страница 25: ...User s Manual of IMG 2x00T Modbus Gateway Series 25 2 1 6 Serial Port Pin Define 2 1 7 4 pin Terminal Block PIN Assignment...

Страница 26: ...section for knowing the information about how to wire the power The power LED on the Industrial Serial Server will light up Please refer to the LED Indicators section for indication of LED lights 5 P...

Страница 27: ...ods to install the Modbus Gateway DIN rail mounting and wall mount plate mounting Please read the following section and perform the procedure in the order being presented Follow all the DIN rail insta...

Страница 28: ...0T Modbus Gateway Series 28 Step 3 Check whether the DIN rail bracket is tightly on the track Please refer to the following procedure to remove the Modbus Gateway from the track Step 4 Lightly remove...

Страница 29: ...ove the DIN rail bracket from the Modbus Gateway Use the screwdriver to loosen the screws to remove the DIN rail bracket Step 2 Place the wall mount plate on the rear panel of the Modbus Gateway Step...

Страница 30: ...x UNIX or other platforms compatible with TCP IP protocols Workstation is installed with Ethernet NIC Network Interface Card Network cables Use standard network UTP cables with RJ45 Use Multi mode or...

Страница 31: ...nd the default subnet mask is 255 255 255 0 Figure 3 2 1 Web Management You can then use your Web browser to list and manage the Modbus Gateway configuration parameters from one central location just...

Страница 32: ...nu in the middle of the Web page lets you access all the functions and statuses It appears as shown in Figure 3 2 4 Figure 3 2 4 Main menu Now you can use the Web management interface to continue the...

Страница 33: ...sks for user name and password for remote login when using Telnet please use the following default IP address username and password for the first time login Default IP Address 192 168 0 100 Default Us...

Страница 34: ...ity as the following screen appears Figure 3 4 1 Planet Smart Discovery Utility Screen If there are two LAN cards or above in the same administrator PC choose a different LAN card by using the Select...

Страница 35: ...setting on multi devices Update All Use current setting on whole devices in the list The same functions mentioned above also can be found in Option tools bar 3 To click the Control Packet Force Broad...

Страница 36: ...Web site Please locate and run the setup program mbgsetup exe and follow the on screen instructions download link https www planet com tw en support downloads method keyword keyword MG view 6 list Af...

Страница 37: ...s Manual of IMG 2x00T Modbus Gateway Series 37 Then waiting for searching the Modbus device the result will as shown below At last select the Modbus devices then click OK to add the device as shown b...

Страница 38: ...use network ports The Modbus Gateway can be configured through an Ethernet connection making sure the manager PC must be set to the same IP subnet address with the Modbus Gateway For example the defa...

Страница 39: ...name password you have changed via console to log in the main screen of Modbus Gateway The login screen in Figure 4 1 2 appears Figure 4 1 2 Login Screen 3 After a successful login the main screen app...

Страница 40: ...unctions that are listed in the Main Function The screen in Figure 4 1 5 appears Figure 4 1 5 Modbus Gateway Main Functions Menu Object Description Basic The essential device information of Modbus Gat...

Страница 41: ...onsole Email Configure management methods on this page Set up the SMTP mail parameters for further operation of events 4 2 1 System The System page provides basic information for the current device Sy...

Страница 42: ...v4 configuration IP Address The current IPv4 address of the device Subnet Mask The current IPv4 subnet mask of the device Gateway The current IPv4 gateway of the device Primary DNS The current first D...

Страница 43: ...e of Modbus Gateway Baud Rate The rate of data transmission to and from the attached modbus serial device Stop Bits The stop bit follows the data and parity bits in serial communication It indicates t...

Страница 44: ...required to save changed configuration and reboot system Therefore the new configuration will be applied after rebooting 4 2 4 Time This page provides configuration of NTP server and Time modificatio...

Страница 45: ...ess to the web console The default is Enable Remote Console To enable or disable access to the remote console The default is Enable Current Time To check whether the reset button is working or not The...

Страница 46: ...P Server From Enter the sender s e mail address This address is used for replying e mails To Enter the receiver s e mail address Alert Events Object Description Cold Start Alert To Enable the Cold Sta...

Страница 47: ...n Figure 4 3 1 appears Figure 4 3 1 Accessible IP Setup Page Screenshot The page includes the following fields Object Description Active Configure the accessible IP list Possible modes are Disabled Di...

Страница 48: ...e default value is static static Set a fixed IPv4 address that was manually configured for a device DHCP Set IPv4 address automatically assigned from a DHCP server IP Address The current IPv4 Address...

Страница 49: ...reenshot Object Description Operation Mode Used to set Modbus serial on serial port The Default is RTU Slave Disable RTU Slave RTU Master ASCII Slave ASCII Master Baud Rate The rate of data transmissi...

Страница 50: ...spend and resume data transmission to ensure that data is not lost It supports four methods and default value is none None RTS CTS Xon Xoff DTR DSR RTS ON delay This parameter controls RTS turn on bef...

Страница 51: ...de can be set up as Disable RTU Slave Master and ASCII Slave Master The operation mode screen in Figure 4 5 3 appears Figure 4 5 3 Operation Mode Screenshot 4 5 2 1 Disable mode When selecting disable...

Страница 52: ...er slave topology in Figure 4 5 5 appears Figure 4 5 5 RTU Slave Topology The remote pair master mode screenshot in Figure 4 5 6 appears Figure 4 5 6 RTU Slave Mode Screenshot 4 5 2 3 RTU Master mode...

Страница 53: ...ave mode This function allows the users to use Modbus TCP master device and Modbus ASCII device to achieve communication The operation mode of the gateway is set to ASCII Slave The TCP server mode top...

Страница 54: ...4 5 11 appears Figure 4 5 11 ASCII Master Mode Topology The TCP client mode screenshot in Figure 4 5 12 appears Figure 4 5 12 ASCII Master Mode Screenshot 4 5 3 MB COM This page is to create virtual...

Страница 55: ...age includes the following fields Object Description Operation Mode Used to set Modbus serial on serial port The Default is RTU Slave Disable RTU Slave RTU Master ASCII Slave ASCII Master Baud Rate Th...

Страница 56: ...ng Status Page Screenshot In block 1 it s a setting value for slave ID 1 3 that will forward to serial port 1 When you get a Modbus requests with slave ID 1 3 it will follow this rule to be routed to...

Страница 57: ...on t need to set the rule manually If the Auto Device Routing is enabled it will clear Slave ID Mapping value of the rule with serial port automatically When you get a request with slave ID didn t exi...

Страница 58: ...e IP218 to wait the initial delay setting before booting completes Listen Port This parameter default 502 means the TCP port t communicates with the connected device TCP Exception If this setting is e...

Страница 59: ...s above it means the request from serial port 1 or 192 168 0 123 will be considered a priority request The screen in Figure 4 5 20 appears Figure 4 5 20 Master Setup Page Screenshot 4 5 5 2 TCP It is...

Страница 60: ...User s Manual of IMG 2x00T Modbus Gateway Series 60 Figure 4 5 22 Request Setup Page Screenshot...

Страница 61: ...de operation Community Indicates the security name to map the community to the SNMP Groups configuration Contact The textual identification of the contact person for this managed node together with in...

Страница 62: ...t Description New Password A new password It allows strings like A Z a z _ 0 9 Confirm Password Please enter the user s new password here again to confirm 4 7 2 Load Default A user can reset the confi...

Страница 63: ...ing 1 Click Maintenance Firmware Update 2 The Firmware Update screen is displayed as in Figure 4 7 4 3 Click the button of the Main page the file selection menu pops up for you to choose firmware 4 Se...

Страница 64: ...on changes of Modbus Gateway it s required to save changed configuration and reboot system Therefore the new configuration will be applied after rebooting The Save and Restart screen in Figure 4 8 1 a...

Страница 65: ...T Modbus Gateway over the network You can also run MB VCOM Utility from one location to manage multiple device servers The setup program will be named mbgsetup exe 5 1 Installing the VCOM Utility 1 Wh...

Страница 66: ...Manual of IMG 2x00T Modbus Gateway Series 66 Figure 5 1 2 Installing location 3 The setup wizard will show the progress of the installation and status as shown in Figure 5 1 3 Figure 5 1 3 Installing...

Страница 67: ...Modbus Gateway Series 67 4 Click Finish to successfully complete installation of VCOM software as shown in Figure 5 1 4 Figure 5 1 4 Installation Finished 5 Restart computer as shown in Figure 5 1 5 F...

Страница 68: ...ess to network as shown in Figure 5 2 1 Figure 5 2 1 Searching Devices 2 After adding an MG 110 device as shown in Figure Figure 5 2 2 When you close searching window it will add device automatically...

Страница 69: ...s for com port mapping as shown in Figure 5 3 1 Figure 5 3 1 VCOM software Add Virtual COM port 1 Click Search to search the network for device servers 2 Once a server has been found select it to add...

Страница 70: ...User s Manual of IMG 2x00T Modbus Gateway Series 70 4 From the Windows Device Manager four COM Ports are added to the device list as shown in Figure 5 3 4 Figure 5 3 4 Virtual COM Ports...