Industrial IP67-rated 6-Port Gigabit

Managed Ethernet Switch

(-40~75 degrees C)

 IGS-5227-6T/IGS-5227-6MT/IGS-5227-6MT-X

Quick Installation Guide

Содержание IGS-5227-6MT

Страница 1: ...Industrial IP67 rated 6 Port Gigabit Managed Ethernet Switch 40 75 degrees C IGS 5227 6T IGS 5227 6MT IGS 5227 6MT X Quick Installation Guide...

Страница 2: ...45 8 pin Straight through UTP Cabling 11 6 M12 X coded Connector Pin Assignment 12 7 M12 8 pin X coded Male to RJ45 8 pin Straight through UTP Cabling 13 8 Connecting M12 Cable to the IGS 5227 6MT IGS...

Страница 3: ...e following items z z The Industrial Managed Switch IGS 5227 6T IGS 5227 6MT IGS 5227 6MT X x 1 z z Quick Installation Guide x 1 z z 1 2m M12 Power Cable x 1 z z Waterproof RJ45 Connector IGS 5227 6T...

Страница 4: ...instructions and follow the procedures in the order being presented Step 1 Take a waterproof RJ45 jack out from the Industrial Managed Switch box and get hold of one RJ45 cable Step 2 Insert the RJ45...

Страница 5: ...raight through cable connection Straight Cable SIDE 1 SIDE 1 SIDE 2 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 SIDE 2 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 Brown 1 Whi...

Страница 6: ...IGS 5227 6T 2 If the waterproof RJ45 connector is found missing or damaged please contact your local reseller where you purchased from If the new waterproof RJ45 connector is obtained from PLANET make...

Страница 7: ...llow all the connecting waterproof cable steps as shown in the example Step 1 Turn counterclockwise to remove the waterproof screw nuts of a RJ45 port and power input Step 2 Insert the waterproof RJ45...

Страница 8: ...8 Step 3 Turn clockwise to tighten the screw nut of the waterproof RJ45 connector Step 4 Insert the waterproof M12 power connector into the port of the power input...

Страница 9: ...ghten the screw nut of the waterproof M12 power connector Note 1 Make sure to tightly close all interfaces to have waterproof effect 2 Before connecting the DC power cord please check whether your loc...

Страница 10: ...the form of M12 8 pin A coded female connector These ports are designed for Ethernet equipment connection through Cat5 5e UTP cables The M12 8 pin A coded input interface pinout is shown below Pin Con...

Страница 11: ...1 2 BI_DA orange 2 3 BI_DB white green 3 4 BI_DC blue 4 5 BI_DC white blue 5 6 BI_DB green 6 7 BI_DD white brown 7 8 BI_DD brown 8 Note As each Ethernet port of the Industrial Managed Switch is runnin...

Страница 12: ...the form of M12 8 pin X coded female connector These ports are designed for Ethernet equipment connection through Cat5 5e UTP cables The M12 8 pin X coded input interface pinout is shown below Pin Co...

Страница 13: ...1 2 BI_DA orange 2 3 BI_DB white green 3 4 BI_DB green 6 5 BI_DD white brown 7 6 BI_DD brown 8 7 BI_DC White blue 5 8 BI_DC blue 4 Note As each Ethernet port of the Industrial Managed Switch is runnin...

Страница 14: ...shown in the example Step 1 Turn counterclockwise to remove the waterproof screw nuts of an M12 connector and power input Step 2 Insert the M12 UTP male connector into the M12 female Gigabit Ethernet...

Страница 15: ...rt of the power input Step 5 Turn clockwise to tighten the screw nut of the M12 power connector Note Before connecting the DC power cord please check whether your local DC power source is stable Note...

Страница 16: ...M12 DC power cable pin assignment and wiring code V1 positive pin black cable V1 negative pin brown cable V2 positive pin blue cable V2 negative pin white cable Note A Make sure you connect the corre...

Страница 17: ...Ethernet Port Connection z z Network cables Use standard network UTP cables with RJ45 connectors z z The above PC is installed with Web browser and JAVA runtime environment plug in Note It is recommen...

Страница 18: ...ager PC must be set on the same IP subnet address For example the default IP address of the Industrial Managed Switch is 192 168 0 100 then the manager PC should be set at 192 168 0 x where x is a num...

Страница 19: ...cess the Web interface 2 When the following dialog box appears please enter the default user name and password admin The login screen in Figure 11 2 appears Default Username admin Default Password adm...

Страница 20: ...d Switch provides Figure 11 4 Switch Menu Note If you are not familiar with Switch functions or the related param eter press Help icon anytime on the Web page to get the help description Now you can u...

Страница 21: ...RAM to FLASH by executing save startup config command so that the running configuration sequence becomes the startup configuration file which is called configuration save To save all applied changes...

Страница 22: ...oop topology as shown below 3 Power on the Industrial Managed Switch and 6 LNK ACT LEDs will be lit 4 Resetting Industrial Managed Switch to the factory default is done when 6 LNK ACT LEDs are lit aga...

Страница 23: ...tw en support faq php type 1 Switch support team mail address support_switch planet com tw IGS 5227 6T IGS 5227 6MT IGS 5227 6MT X User s Manual http www planet com tw en support download php type1 22...

Страница 24: ......