![Planet IGS-5225 Series Скачать руководство пользователя страница 291](http://html1.mh-extra.com/html/planet/igs-5225-series/igs-5225-series_user-manual_1563274291.webp)
User’s Manual of IGS-5225 series
291
frame is classified to the PCP value in the tag. Otherwise the
frame is classified to the default PCP value.
•
DEI
Controls the default
All frames are classified to a DEI value.
If the port is VLAN aware and the frame is tagged, then the
frame is classified to the DEI value in the tag. Otherwise the
frame is classified to the default DEI value.
•
CoS ID
Controls the default
Every incoming frame is classified to a CoS ID, which later can
be used as basis for rewriting of different parts of the frame.
•
Tag Class.
Shows the classification mode for tagged frames on this port.
Disabled
Enabled
Click on the mode in order to configure the mode and/or
mapping.
Note:
This setting has no effect if the port is VLAN unaware.
Tagged frames received on VLAN unaware ports are always
classified to the default CoS and DPL.
•
DSCP Based
Based QoS Ingress Port Classification.
•
WRED Group
•
Ingress Map
selection through the Map ID. The Ingress Map ID
ranges from
0
to
255
. An empty field indicates no map selection.
•
Egress Map
selection through the Map ID. The Egress Map ID
ranges from
0
to
511
. An empty field indicates no map selection
Buttons
: Click to apply changes
: Click to undo any changes made locally and revert to previously saved values.
4.4.1.2 Queue Policing
This page allows you to configure the Queue Policer settings for all switch ports.. The Queue Policing screen in
Figure 4-4-1-2
appears.
Содержание IGS-5225 Series
Страница 1: ...User s Manual of IGS 5225 series 1 ...
Страница 34: ...User s Manual of IGS 5225 series 34 ...
Страница 35: ...User s Manual of IGS 5225 series 35 IGS 5225 8P2T2S IGS 5225 8P2T2S Dimensions W x D x H 72 x 107 x 152 mm ...
Страница 36: ...User s Manual of IGS 5225 series 36 IGS 5225 8P4S IGS 5225 8P4S Dimensions W x D x H 72 x 107 x 152 mm ...
Страница 37: ...User s Manual of IGS 5225 series 37 IGS 5225 4P2S IGS 5225 4P2S Dimensions W x D x H 50 x 87 8 x 135 mm ...
Страница 38: ...User s Manual of IGS 5225 series 38 IGS 5225 4T2S IGS 5225 4T2S Dimensions W x D x H 32 x 87x 135 mm ...
Страница 57: ...User s Manual of IGS 5225 series 57 Figure 2 18 Wiring DO0 and DO1 to Open Detector ...
Страница 79: ...User s Manual of IGS 5225 series 79 Figure 4 1 5 Industrial Managed Switch Main Functions Menu ...
Страница 199: ...User s Manual of IGS 5225 series 199 Figure 4 3 4 6 STP CIST Port Configuration Page Screenshot ...
Страница 265: ...User s Manual of IGS 5225 series 265 Click to undo any changes made locally and revert to previously saved values ...
Страница 288: ...User s Manual of IGS 5225 series 288 ...