4.3.3.9 MAC-based VLAN
The MAC-based VLAN entries can be configured here. This page allows for adding and deleting MAC-based VLAN entries and
assigning the entries to different ports. This page shows only static entries. The MAC-based VLAN screen in
Figure 4-3-3-16
appears.
Figure 4-3-3-16:
MAC-based VLAN Membership Configuration Page Screenshot
The page includes the following fields:
Object
Description
•
Delete
To delete a MAC-based VLAN entry, check this box and press save.
•
MAC Address
Indicates the MAC address.
•
VLAN ID
Indicates the VLAN ID.
•
Port Members
A row of check boxes for each port is displayed for each MAC-based VLAN entry.
To include a port in a MAC-based VLAN, check the box. To remove or exclude
the port from the MAC-based VLAN, make sure the box is unchecked. By default,
no ports are members, and all boxes are unchecked.
•
Adding a New
MAC-based VLAN
Click “Add New Entry” to add a new MAC-based VLAN entry. An empty row is
added to the table, and the MAC-based VLAN entry can be configured as
needed. Any unicast MAC address can be configured for the MAC-based VLAN
entry. No broadcast or multicast MAC addresses are allowed. Legal values for a
VLAN ID are 1 through 4095.
The MAC-based VLAN entry is enabled when you click on "Save". A MAC-based
VLAN without any port members will be deleted when you click "Save".
The “Delete” button can be used to undo the addition of new MAC-based VLANs.
Buttons
: Click to add a new MAC-based VLAN entry.
Содержание IGS-5225 Series
Страница 1: ...User s Manual of IGS 5225 series 1 ...
Страница 34: ...User s Manual of IGS 5225 series 34 ...
Страница 35: ...User s Manual of IGS 5225 series 35 IGS 5225 8P2T2S IGS 5225 8P2T2S Dimensions W x D x H 72 x 107 x 152 mm ...
Страница 36: ...User s Manual of IGS 5225 series 36 IGS 5225 8P4S IGS 5225 8P4S Dimensions W x D x H 72 x 107 x 152 mm ...
Страница 37: ...User s Manual of IGS 5225 series 37 IGS 5225 4P2S IGS 5225 4P2S Dimensions W x D x H 50 x 87 8 x 135 mm ...
Страница 38: ...User s Manual of IGS 5225 series 38 IGS 5225 4T2S IGS 5225 4T2S Dimensions W x D x H 32 x 87x 135 mm ...
Страница 57: ...User s Manual of IGS 5225 series 57 Figure 2 18 Wiring DO0 and DO1 to Open Detector ...
Страница 79: ...User s Manual of IGS 5225 series 79 Figure 4 1 5 Industrial Managed Switch Main Functions Menu ...
Страница 199: ...User s Manual of IGS 5225 series 199 Figure 4 3 4 6 STP CIST Port Configuration Page Screenshot ...
Страница 265: ...User s Manual of IGS 5225 series 265 Click to undo any changes made locally and revert to previously saved values ...
Страница 288: ...User s Manual of IGS 5225 series 288 ...